background image

record FlowControl

User manual

Translation of the original manual

Summary of Contents for FlowControl

Page 1: ...record FlowControl User manual Translation of the original manual ...

Page 2: ...Document identification Article nr 121 006454644 Version 1 3 Publication date 23 03 2021 Subject to technical modifications Copyright agtatec ag ...

Page 3: ...t data analysis and data transfer optional 14 3 6 Operating modes 14 4 Technical data 15 5 Operation 17 5 1 BDE D FC and key functions 17 5 2 Instructional symbols 18 5 3 Menu display 18 5 4 Status display 18 5 5 Select Permission Level 18 5 6 Restart via keyboard 18 5 7 Operating lock via the keyboard 19 5 8 BDE D FC Menu 20 5 9 Viewing and resetting counting statistics 21 5 10 Setting the door c...

Page 4: ...Table of revision 4 28 BAL_FlowControl_EN_1V3_REC_121 006454644 Table of revision B BDE D FC Menu New chapter 20 ...

Page 5: ...ead to severe injury or death DANGER Against an imminent or latent hazardous situation that could lead to electric shock and cause serious injury or death 1 2 Intended purpose of use The system is designed exclusively for use as a pedestrian passage The installation may only occur in dry areas If there are deviations then proper waterproofing and water drains will be required on site Any other app...

Page 6: ...ply overnight ð Settings should only be made by personnel qualified to do so ð Do not disassemble put out of operation or manipulate safety devices ð Have faults rectified by specialist personnel or by personnel qualified to do so ð Have service and maintenance carried out according to locally applicable regulations or accord ing to a maintenance contract CAUTION Risk of malfunctions material dama...

Page 7: ...t is moving ð Do not open or remove protective covers during operation ð Do not permanently remove covers from the system ð Only carry out inspection service maintenance and cleaning when the system is stationary and switched off CAUTION Danger of material damage or injury due to non functioning safety devices a If safety devices are not functioning manipulated or put out of operation there is a r...

Page 8: ...from closing ð Have inspection service and maintenance of the fire protection system carried out in accordance with locally applicable regulations or according to a maintenance contract ð Have the fire protection system checked and maintained according to the state of the art 1 4 State of technology This system was developed using state of the art technology and officially recognized technical saf...

Page 9: ... protects personnel in busy work areas from collisions with vehicles Depending on the place of work and the working environment the protective equipment varies and must be adapted accordingly In addition to protective equipment for specific work the work site may require other protective equipment for example a harness In hygiene protected areas special or additional requirements of personal prote...

Page 10: ...H Carl Benz Str 5 15 D 77972 Mahlberg It is prohibited to reproduce distribute or use the manuals for purpose of competition without the writ ten authorization of BLASI GmbH Violation of the here stated copyrights will be prosecuted and fined with compensation of damage Subject can change without prior notice Differences between product and manual are thereby possible 2 3 Product identification Th...

Page 11: ... referred to as the owner regardless whether he operates it as owner or discloses it to a third party Personnel All individuals referred to as personnel are those who perform any task on or with the system during its lifespan and are qualified to perform such task according to the manufacturers criteria and are therefore deemed authorized Expert Expert refers to all individuals who are authorized ...

Page 12: ...aphical presentation Sliding door Abbreviation Description Abbreviation Description A Passage width J Total height 3 2 Overall view Example for 1 leaf sliding door Pos Components Pos Components 1 Sensor bracket 2 Sensor 3 Control box 4 LED Strips 5 Operating unit 6 Speaker optional ...

Page 13: ...anager Available settings Max allowable people in store Used to trigger customer traffic lights going red disable of door opening and triggering of audio alerts see below Pre alert trigger for Customer Service Desk message as of Max count Staff alert is both custom audio mes sage and halo LED visual indicator around speaker Can be set above 100 if needed Delay time before Please Wait Here customer...

Page 14: ...unt Manual adjustments made to count Manual adjustments made to count NOTICE Remote Data All data is live currently updated once every 30 seconds 3 6 Operating modes Display Operating mode Function Status OFF Counting Inactive LED displays Inactive Interaction with door Inactive Current counter value Current counter value is set to zero EXIT ONLY Counting Active LED displays Red Interaction with d...

Page 15: ... Mounting position electronics Interior Mounting position sensor Interior Dimensions Opening width A max 2200 mm at 3000 mm installation height Passage height G variable Total height J variable Installation height of sensor 2100 3000 mm Min object height to be counted 1300 mm Electrical connection data Mains voltage input 110 230 V AC 50 60 Hz System voltage Peripherals 24 V DC Power consumption S...

Page 16: ...44 VoiceBox optional Speaker Intendance 4 8 Ω Speaker volume 86 dB Speaker frequency range 90 17 000 Hz Environmental conditions Temperature range 15 C to 50 C Moisture range up to 85 rel humidity non condensing Protection class LED Strips IP65 Miscellaneous IP44 ...

Page 17: ...evice on the inside of the door radar MINUS Navigation up when selecting the menu items INFO The INFO button is the access to the settings Different settings are dis played depending on the authorization level see chapter Select Permis sion Level PLUS Navigation down when selecting menu items NOTICE Menu display In this area the keys have the function printed above or below the keys navig ation in...

Page 18: ...splay is as a list the currently selected entry is inverted light text on dark background status parameters Menu statistics 5 4 Status display The status display shows information with status number and message in plain text If there is more than one piece of informa tion the number and the current entry number is also displayed The next entry is called up by pressing the info key 1 2 5 5 Select P...

Page 19: ...ng the control unit Press key sequence Display symbol Description E C The control panel keys are locked Unwanted manipulation of the control unit is made more difficult The locked state of BDE D FC control unit is displayed on the screen with a key sym bol bottom left Unlocking the control unit Press key sequence Display symbol Description E C The control panel keys are activated Free selection of...

Page 20: ...D blinking OFF ON LEDs flash red when the counter reaches the set limit Blink duration 5 s Duration of how long the LEDs flash After that continuous light Blink Interval 500 ms Flashing frequency speed of flashing Voice output ON ON OFF Voice output Repeat Pause 30 s Pause time of voice output message 1 if max pers reached Repeat Pause OK 0 s Pause time for voice output message 2 if max pers is un...

Page 21: ... Selection Description Statistics n a The In operation Count records all counts in entrance direction per usage Maximum 15 entries possible the 16th entry automatically overwrites the 1st entry Cnt Log Reset counting statistics Path Selection Description Statistics Yes The Total Count is reset All entries in In operation Count are reset Reset cnt No 5 10 Setting the door control In the menu Parame...

Page 22: ...vate LED display Path Selection Description Parameter off When the function is activated the LED strips and the counting function are active If the function is deactivated only the count ing function is active Signalisation on LED output Activate deactivate flashing function Path Selection Description Parameter off If the flashing function is activated the LED strips flash when the counter reaches...

Page 23: ...ge Signalisation on Voice output Set interval between speech output Path Selection Description Parameter n a Duration between each language output set in seconds The parameter Repeat delay is triggered by reaching the maximum number of per sons Signalisation Repeat delay Set interval between speech output Path Selection Description Parameter n a Duration between each language output set in seconds...

Page 24: ... transmission are cleaned and adjusted Rel evant fixing screws are controlled and retightened if necessary Then functional testing is carried out for switching devices drives control units force or energy stor ing devices or command controllers The safety devices are adjusted and all the motion sequences including the final points are set A test run with final overall control of the door system is...

Page 25: ...ed result Sensors and LED strips Walk towards the door at normal speed from the inside and out side If necessary clean the sensors and LED strips Please note Moisture condensa tion on the sensor due to the es cape of warm moist internal air and condensation on the colder external motion sensor can pre vent the door from closing Dehu midify the interior air or wipe the outer sensor dry if necessary...

Page 26: ...e display of the BDE D FC operating unit This information gives the service technician important information for possible troubleshooting Malfunction Display icon Description Error display Error is pending Contact Service No indication Check connections Contact Service CAN malfunction No connection to the controller Contact Service 7 1 2 Possible troubleshooting Based on the status display malfunc...

Page 27: ...letely disassembled in reverse order The automatic door mainly consists of the following materials Aluminum Linking profiles Gearbox Drive panel Door wing profiles and side profiles Various profiles and small parts Steel iron parts Stainless steel casing Floor panel Box recess for floor installation Optional spacer or reinforcement profiles Gear components springs Various small parts like fittings...

Page 28: ...and www record de Denmark www record danmark dk España www record es France www record fr Malaysia www recorddoors my Polska pl record global Schweiz www record ch Sverige www record se Türkiye tr record global United States www recorddoors com record global export www record global Subject to technical modifications Copyright agtatec ag No 121 006454644 ...

Reviews: