Operation
5
BAL_FlowControl_EN_1V3_REC_121-006454644
21 / 28
5.9
Viewing and resetting counting statistics
NOTICE
Switching with the ON / OFF key , creates a new entry in the system (In-operation
Count).
A maximum of 15 entries are possible, after which a new entry replaces the oldest counter
value.
The user can retrieve and reset various counting statistics via the
BDE-D FC.
cnt. log
reset cnt.
statistics
total cnt.
Viewing count statistics Total Count
Path
Selection
Description
Statistics
n/a
– The
Total Count
continuously records all
the passages in the entrance direction.
→
Total cnt.
View Count Statistics In-operation Count
Path
Selection
Description
Statistics
n/a
– The
In-operation Count
records all counts
in entrance direction per usage.
– Maximum 15 entries possible, the 16th
entry automatically overwrites the 1st entry.
→
Cnt. Log
Reset counting statistics
Path
Selection
Description
Statistics
Yes
– The
Total Count
is reset.
– All entries in
In-operation Count
are reset.
→
Reset cnt.
No
5.10
Setting the door control
In the menu Parameter / Signalling the door control can be activ-
ated / deactivated when the person limit is reached.
Signalisation
Door Contr.
Activate / deactivate flashing function
Path
Selection
Description
Parameter
off
– If the function is activated, the door is auto-
matically deactivated when the person limit
is reached.
– If the function is deactivated, the door is not
deactivated when the person limit is
reached.
→
Signalisation
on
→ →
Door control