MEI CASHFLOW SC83 Page-24
www.meigroup.com Part # 252055088 G3
9)
Can a CASHFLOW
TM
SC83 unit be calibrated in the Field?
A CASHFLOW
TM
SC83 unit can not be calibrated in the field. The CASHFLOW
TM
SC83
is designed not require field calibration. Calibration is only required after certain repairs
that are done to a CASHFLOW
TM
SC83 unit. Therefore, only an approved CASHFLOW
TM
SC83 Service Center are trained to calibrate a CASHFLOW
TM
SC83 unit.
10)
What are the differences among model #s?
SC8300
is a generic unit that has no recognition or interface software installed in it. It also
does not have a harness attached to the chassis.
SC8302
is a Flash unit made to interface to IGT’s Netplex machines. It uses the IGT
ID024 interface.
SC8302 P
is a PROM unit made to interface to IGT’s Netplex machines. It uses the IGT
ID024 interface.
SC8304
is a Flash unit made to interface to various machines. It uses MEI Opto Isolated
EBDS Interface.
SC8304 P
is a PROM unit made to interface to various machines. It uses MEI Opto
Isolated EBDS Interface.
SC8307
is a Flash unit made to interface to various machines. It uses MEI RS-232 EBDS
Interface.
SC8307 P
is a PROM unit made to interface to various machines. It uses MEI RS-232
EBDS Interface.
11)
What are the differences among interfaces?
MEI EBDS (Extended Bi-Directional Serial) Protocol
is a proprietary MEI protocol
specification used to accomplish two-way serial communication between the note acceptor
and a host machine. It is not used for interfacing to IGT machines. Open collector EBDS
uses opto isolated interface hardware. RS-232 EBDS uses RS-232 level interface hardware.
IGT Netplex (Serial) Protocol
is proprietary IGT interface used to communicate
between the IGT host machine and the note acceptor.
FREQUENTLY ASKED QUESTIONS