background image

                            MEI CASHFLOW SC83  Page-20

www.meigroup.com                                                        Part # 252055088 G3

Non Committed Contacts

Depending on the  desired interface, the SC83XX may be supplied with one or two sets of non
committed contact leads for OEM use. The contacts are rated at 125VAC, 5AMPs Maximum.
Wire connections are as follows:

Maintenance

Periodic maintenance can improve the performance and extend the working life of  a note
acceptor. Additional attention may be required if  the note acceptor becomes inoperable due to a
jammed object or acceptance rates fall below normal.

Cleaning the Acceptor Module

Note: You must remove the acceptor module from the chassis to open the front sensor area. Forcing the note path open without removing the
acceptor module from the chassis will damage the unit. Remember to turn off the machine (as per machine manufacturer) when performing any
cleaning.

• Remove the acceptor module from the chassis. (Instructions on how to
remove it are on page 10).

• Open the acceptor module by placing the palm of your hand on the front of
the module and placing your fingers around the top of the yellow cover as
shown in the diagram to the right.  Pull the cover toward your hand and then
lift up, opening the module head fully.

• Clear the note path area of  any foreign objects.

• Wipe the note path and sensor areas as needed with a soft damp cloth.  For
stubborn dirt, a small amount of mild non-abrasive soap may be added to the
water before dampening the cloth. Make sure no streaks or residual soap remain on the note path.

Note: SC83 does not require the use of a cleaning card. Never use a petroleum-based product to clean this device! Petroleum based products
will damage the note path. Mild non-abrasive soap is preferred over alcohol.

Calibration

The SC83 series note acceptor was designed not to require calibration. Thus, the unit has no
switch settings or calibration mode that allows a user to perform a calibration. Calibration may
only be performed by MEI trained technicians.

Black OEM SW1 or 2 , COM
White OEM SW1 or 2 , NC
Red

OEM SW1 or 2 , NO

Summary of Contents for Cashf low SC83

Page 1: ...MEI CASHFLOW SC83 Page 1 www meigroup com Part 252055088 G3 MEI Cashflow SC83 Installation Operation Manual MEI Inc 2007...

Page 2: ...MEI CASHFLOW SC83 Page 2 www meigroup com Part 252055088 G3...

Page 3: ...rley Redding RG6 1AZ United Kingdom Internet http www meigroup com MEI Inc 2007 Except as permitted under the relevant local legislation no part of this publication may be copied transmitted transcrib...

Page 4: ...alling Locks on the Cashbox 13 UPDATINGSOFTWARE Cashflow Programing Module CPM 14 15 Replacing the PROM 16 18 HARNESSINGAND CONNECTORS EBDS Interface Pin Out 19 RS232 Interface Pin Out 19 MAINTENANCE...

Page 5: ...tured Last digit of year Week Manufactured 0 52 Sequential Production Number Model Number 00 OEM Configurable No Harness 02 OEM Proprietary 04 Opto Isolated EBDS 07 RS232 EBDS Flash Unit blank P PROM...

Page 6: ...MEI CASHFLOW SC83 Page 6 www meigroup com Part 252055088 G3 OVERVIEW COMPONENTS Acceptor Module Chassis Cashbox...

Page 7: ...OR SHORT NOTE PATH DURABLE WELDED PLASTIC EXTERIOR RECESSED PLASTIC GEARS DUAL LOCK CAPABILITY COMMON ACCEPTOR MODULES PC STYLE EDGE CONNECTOR INTERFACE CARDS ACCEPTOR RELEASE LATCH NOTE PATH RELEASE...

Page 8: ...odels Entry guides for the SC83 Not all entry guides fit in every machine Your choice regarding entry guides will depend on machine specifications Below are three entry guides that MEI currently manuf...

Page 9: ...interference with any equipment operation Note If you have a custom configuration you may need to contact our technical support group for assistance Once the connections are made you will need to lin...

Page 10: ...t the Acceptor Module so that the release lever locks into place The acceptor should be firmly seated to ensure proper engagement of the locking feature To remove the unit pull upwards on the release...

Page 11: ...entry guide to the eight pin connector located on the left hand side of the face of the acceptor module Make sure that the entry guide is aligned so the machine door closes properly Acceptor Module e...

Page 12: ...ert the cashbox all the way in so that the rear of the cashbox is flush against the chassis wall Removing the Cashbox When the note acceptor is installed in a machine you just need to grab the yellow...

Page 13: ...ying policies etc The customer is responsible for selecting a lock with performance that is fit for the intended purpose MEI does not test or endorse any specific brand of lock for security characteri...

Page 14: ...he Cashflow Programming Module See fig 1 below 2 Plug the type A end of your USB harness to the USB type A port of the CPM Plug the type B end of the same USB harness into the USB type B port of the C...

Page 15: ...on the CPM will turn off 4 Disconnect the USB harness from the Cashflow SC83 once the LEDs on the CPM are off 5 Once dowload is complete the Cashflow SC83 s diagnostic LEDs will flash five times green...

Page 16: ...module from the chassis Instructions on how to remove it are on page 10 2 Open the acceptor module by placing the palm of your hand on the front of the module and placing your fingers around the top o...

Page 17: ...cing the programmed PROM Continued 5 You may now remove the PROM using a PLC puller 6 Insert the new PROM Replacing the yellow cover Note To install the yellow cover the acceptor module must remain op...

Page 18: ...he programmed PROM Continued 8 Once in position move the yellow cover forward as if you were opening the acceptor module until the cover locks into place 9 Close the acceptor module and re install it...

Page 19: ...d2 2 6 Pink RS232 EBDS RXD1 L 7 Blue Power 2 B 8 Purple LED Supply 9 9 Not Populated 10 Not Populated 11 Green Power 1 A 12 Tan RS232 EBDS TXD1 K NOTES 1 RXD refers to input to the note acceptor TXD i...

Page 20: ...how to remove it are on page 10 Open the acceptor module by placing the palm of your hand on the front of the module and placing your fingers around the top of the yellow cover as shown in the diagram...

Page 21: ...or fault Replace the acceptor with a programmed spare 2 Flash Red Interface board hardware fault Replace the interface board 3 Flash Red Invalid Config Coupon Cash Box Memory Fault 4 Flash Red Solid R...

Page 22: ...led on the note acceptor Some entry guides do not plug into the note acceptor they plug directly to the host machine 4 How is software updated in CASHFLOWTM SC83 Flash units and PROM units in the fiel...

Page 23: ...ces Green 3 flashes Not used Green 4 flashes Not used Yellow Solid Cash Box unseated Cash Box not present To be able to reset the not present Cash Box Yellow 1 flash Poor Acceptance Need for cleaning...

Page 24: ...machines It uses the IGT ID024 interface SC8304 is a Flash unit made to interface to various machines It uses MEI Opto Isolated EBDS Interface SC8304 P is a PROM unit made to interface to various mach...

Page 25: ...e rate drops below normal 14 Can I use alcohol to clean a CASHFLOWTM SC83 unit Alcohol is not the preferred cleaning solution Refer to Question 13 15 Can I use cleaning cards Not necessary Cleaning ca...

Page 26: ...Like model number acceptors may be easily swapped i e SC8302 to another SC8302 Consider the machine denomination and verify that the correct notes are enabled disabled and that any entry guide place...

Page 27: ...MEI CASHFLOW SC83 Page 27 www meigroup com Part 252055088 G3 DRAWINGS...

Reviews: