Line and probe location in “Ferrolux” mode
65
The typical emission characteristic of a probe causes, at the surface, the waveform
shown in the following figure, which is characterized by two minimum positions.
Use the following procedure to locate the position of a probe.
Step Action
1
Activate probe location mode (see page 45).
Result:
The
symbol indicates that probe location mode is activated. A
compass needle appears in the centre of the display, which - if the receiver is
correctly aligned - indicates the direction of the probe.
2
Select the frequency of the probe or the transmitter to which the probe is
connected (see page 45).
The locating mode cannot be changed. Probe location is always conducted in
maximum mode.
3
If possible, push the probe only a few metres into the line initially; this will allow
you to assess its position with reasonable accuracy.
Procedure