background image

TWO-CHANNEL RECEIVER ROM-22 

OPERATION MANUAL

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamel.com

, e-mail: [email protected]

plik: ROM-22_inst_ext_gb | modyfikacja: 30.05.2018

The symbol means selective 

collecting of electrical and electronic 

equipment. It is forbidden to put the 

used equipment together with other 

waste.

APPEARANCE

FEATURES

TECHNICAL DATA

DESCRIPTION

●  Rated supply voltage 230 V AC.

●  Compatible with EXTA LIFE system control-

ler and transmitters.

●  With  2  output  channels  (2  x  potential-free 

NO/NC switchable contacts).

●  Two-way transmission with an indication of 

each output status in the application.

●  Programmable  output  status  after  supply 

voltage loss.

●  2 programmable external inputs.

●  For connecting monostable or bistable con-

nectors.

●  4 operating modes when working with trans-

mitters  (activate/deactivate,  bistable,  mon-

ostable, time).

●  2 operating modes when working with con-

troller (activate/deactivate, time).

●  Independently programmable time for radio 

transmitters, external inputs and for control-

ler.

●  Times assigned independently for each out-

put.

●  Software can be updated remotely.

A ROM-22 modular radio receiver is the fi-

nal element of EXTA LIFE system which allows 

individual  control  of  any  two  devices/circuits. 

Two relays with switch contacts (NO/NC) with 

maximum rated load 10A as outputs. This ena-

bles the user to control low voltage circuits (e.g. 

12/24 VAC/DC) and high voltage circuits (230 

VAC). The receiver is also good for remote ac-

tuation of other devices. You can also use it for 

feeding control signals. The ROM-22 receiver is 

also suitable for controlling solenoids in heating 

systems.  Thanks  to  bidirectional  communica-

tion  between  the  receiver  and  controller,  you 

can view each receiver channel’s status at any 

particular time on a mobile app. Also, the bidi-

rectional  communication  enables  the  operator 

to change the specific parameters of the receiv-

er and add receivers remotely (i.e. without the 

actual access to the receiver). Frame encryp-

tion algorithm ensures control safety. A receiver 

installed outside a controller may be controlled 

in parallel using the EXTA LIFE system’s trans-

mitters. You can register more transmitters with 

a receiver to enable independent control from 

several locations. Configurable cable inputs in-

crease control functionalities. The receiver has 

a  built-in  remote  software  update  from  a  con-

troller. The product is designed for installing in 

switch  cabinets  using  a TH35  (DIN)  bar.  With 

removable  antenna  to  enable  connecting  an 

external antenna.

Rated supply voltage 230 VAC

Rated frequency 50 / 60 Hz

Rated power consumption

Standby: 0.65 W

One channel active: 1.3 W

Two channels active: 1.9 W

Transmission RF — ISM 868 MHz (868.50 MHz) band

Transmission mode duplex — 9600 bps

Maximum power 14 dBm (25 mW)

Encryption 128-bit key algorithm

Operating range max. 300 m in open areas

Transmitting/programming signalling Yes - green LED (STATUS)

Selected channel / channel status signalling Yes - red LEDs (CH1, CH2)

Maximum number of paired buttons 96 pairs (distributed into 2 channels)

Current channel status information Yes - in EXTA LIFE mobile application

Operation modes in co-operation with EXTA LIFE 

system transmitters Turn on/off, bistable, monostable, time

Operation modes in co-operation with an EXTA LIFE 

controller Turn on, off, timer

Number of external outputs 2

Compatible connectors* monostable (buttons), bistable

Operation modes for external inputs** Turn on/off, bistable, monostable, time

Time setpoint range*** 1 s–18 h

Number of output channels 2

Relay contact parameters 2 x NO/NC 16A / 250 VAC

(Selectable voltage-free contacts) 2 x 10 A / 250 VAC 

Maximum outputs current-carrying capacity 2 x 10 A / 250 VAC

Number of termination points 10 (conductor cross-section up to 2.5 mm

2

)

Enclosure mounting TH35 bar (DIN)

Operating temperature range -10 to +55°C

Enclosure protection rating IP20

Dimensions 90 x 35 x 66 mm (double module)

Weight 0.13 kg

*   Selection of switch possible only from the mobile app level coupled with the EFC-01 controller.

**   Input operating mode selection depends on the type of selected coupler type.

***  Times are assigned independently to each channel of the receiver. The periods are programmed separately for 

buttons operating in time mode, external inputs and for control from the app level.

Zamel Sp. z o.o. hereby declares that the 

ROM-22 radio equipment type conforms 

to Directive 2014/53/EU.

Transmit/receive signalling

/ status during programming operations

PROG. button - programming

Diodes for signalling currently selected 

channel during programming / channel status 

during normal operation

Antenna socket

Output terminals  (channel  2)

Input terminals for cable control

(by default works with monostable connectors)

Output terminals  (channel  1)

Power terminals

Summary of Contents for EXTA LIFE ROM-22

Page 1: ...onfigurable cable inputs in crease control functionalities The receiver has a built in remote software update from a con troller The product is designed for installing in switch cabinets using a TH35 DIN bar With removable antenna to enable connecting an external antenna Rated supply voltage 230 VAC Rated frequency 50 60 Hz Rated power consumption Standby 0 65 W One channel active 1 3 W Two channe...

Page 2: ... button several quick blinks of STATUS LED occur and CH2 LED turns off TIME MODE Step_1 Pairing a selected button with receiver 1 Briefly press 1 s the PROG button on the receiver CH1 LED lights up 2 Briefly press 1 s the PROG button on the receiver again CH2 LED lights up and CH1 LED will turn off 3 Wait approx 2 s until STATUS LED lights up After the STATUS LED is lit within 5 s briefly press an...

Page 3: ...ttons 5 After pressing the button the STATUS LED will start blinking which informs that you entered deleting procedure Completion of the deleting procedure is sig nalled by the STATUS and CH2 LEDs going off DELETING TRANSMITTERS USING EXTA LIFE APP REMOTE The receiver from which you want to remotely delete receivers buttons must be paired with an EXTA LIFE controller To remotely delete buttons fro...

Page 4: ...lso includes unpairing deletion of the receiver from the EXTA LIFE controller as a result it will not be possible to control the system using the application If there are buttons entered in time mode in the receiver s memory then after clearing the memory the assigned times were also cleared Global time assumes the default value of 10 s To clear the complete receiver s memory do the following 1 Pr...

Page 5: ...e operating mode may be changed only using EXTA LIFE mobile app working with EFC 01 controller see Input functionality 6 After installing the receiver check it for proper operation When using EXTA LIFE system transmit ters for control you must first program them with a receiver see Programming the transmitters To work with the controller the receiver must be properly paired with the controller see...

Reviews: