Technical description
13
2.2
Technical data
The indicator unit is defined by the following technical parameters:
Parameter
Value
Power supply
6 x AA batteries, type IEC R6 (alkaline manganese)
Operating time
>15 hours
Voltmeter
•
Input resistance
•
Measurement range
•
Sensitivity
(Only with ESG mode enabled)
650 kΩ
max. 200 V
<5
μV
Operating temperature
-20 °C – 55 °C
Operating humidity
Max. relative humidity 93% at 30 °C
Storage temperature
-30 °C – 70 °C
Display
TFT colour display with 320 x 240 pixels
Headphone connection
Via 3.5 mm jack socket or Bluetooth interface
Weight
<0.9 kg
Dimensions
225 mm x 65 mm x 100 mm (W x H x D)
IP protection class
(in
accordance with IEC 60529
(DIN VDE 0470-1))
IP 54
The DPP-SU sensor is defined by the following parameters:
Parameter
Value
Acoustic amplification
>120 dB (facility for limiting amplification to 84
dB(A) can be switched on and off)
Dynamic range
•
Acoustic channel
•
Magnetic channel
>110 dB
>110 dB
Acoustic frequency range
100 to 1500 Hz
Acoustic filters
Software-activated filters for improving acoustic
perception
Noise suppression
Patented noise suppression (BNR) (software-
activated)
Automatic mute
Proximity sensor for automatic mute
Trigger threshold setting
Can be switched between automatic and manual
setting
Error direction detection
Automatic
Weight
(incl. telescopic handle)
<2.2 kg
Dimensions
230 mm x 140 mm (Ø x H)
IP protection class
(in
accordance with IEC 60529
(DIN VDE 0470-1))
IP 65 (only for plugged-in connector)
Indicator unit
DPP-SU sensor(