Specifications
AVTMDELTA4000-EN Rev 6 April 2018
11
Maximum Specimen Capacitance
Table 1 shows the maximum measurable specimen capacitance at various
voltages and loading time. This can be increased up to 1.2
µ
F at 10 kV (50 Hz)
test voltage using the optional Resonating Inductor.
Table 1: Maximum Measureable Specimen Capacitance at 50/60Hz
Test
Volts
(kV)
Maximum Capacitance
(
µ
F)
(100 mA continuos
service)
Maximum Capacitance
(
µ
F)
(300 mA for 4 minutes)
60 Hz
50 Hz
60 Hz
50 Hz
0.025
11
13
32
38
0.05
5.3
6.3
16
19
0.1
2.6
3.2
7.9
9.5
0.25
1.1
1.3
3.2
3.8
0.5
0.53
0.63
1.6
1.9
1
0.26
0.32
0.79
0.95
2
0.13
0.16
0.40
0.48
3
0.09
0.11
0.27
0.32
4
0.065
0.080
0.20
0.24
5
0.11
0.063
0.16
0.19
6
0.044
0.055
0.13
0.16
8
0.033
0.040
0.099
0.12
10
0.027
0.032
0.080
0.095
12
0.022
0.027
0.066
0.080
ALL FREQUENCIES AND LIMITS ARE LISTED IN SECTION 3 –