Continuity (
BM80/2
&
BM81/2
only)
Measurement:
0,01
Ω
to 99,9
Ω
(0 to 50
Ω
on analogue scale)
Accuracy:
± 2% ± 2 digits
Open circuit voltage:
5 V ± 1 V
Test current:
205 mA ± 5 mA (0 - 10
Ω
)
Zero offset at probe tips:
0,10
Ω
typical
Lead resistance zeroing:
Up to 9,99
Ω
Bleeper:
Operates at less than 5
Ω
(approx).
Resistance
Measurement:
0,1 k
Ω
to 100 k
Ω
(0 to 10 M
Ω
on analogue scale)
Accuracy:
± 3% ± 2 digits
Open circuit voltage:
5 V ±1 V
Short circuit current:
20 µA ± 5 µA
Voltage
Analogue Scale
Measurement
Accuracy(>1 V)
0 to 500 V Range
0 to 450 V d.c. or a.c. (50/60 Hz)
± 1% ±2 digit
450 to 600 V d.c. or a.c. (50/60 Hz)
± 1% ±2 digit
0 to 450 V 400 Hz a.c.
± 5% ±2 digits
0 to 50 V Range
0 to 50,0 V d.c. or a.c. (50/60 Hz)
± 2% ±2 digits
Default Voltmeter
Operates at >25 volts a.c. or d.c. on any range except OFF and Battery check. Reverse polarity
d.c. will cause '-dc' to appear in the display.
15
Specification
Summary of Contents for BM80/2 Series
Page 19: ...Typical Terminal Voltage Characteristics 18 BM80 2 BM82 2 only...
Page 22: ...21...
Page 42: ...Caract ristiques types de tension de borne 41 BM80 2 BM82 2 seulement...
Page 45: ...44 M BM80 2 Serie Mehrfachspannungs Isolations und Durchgangspr fer Gebrauchsanleitung...
Page 64: ...Charakteristika einer typischen Anschlu spannung 63 nur bei BM80 2 und BM82 2...
Page 67: ...66 M Serie BM80 2 Probador de aislamiento y continuidad de voltaje multiple Gu a del Usuario...
Page 86: ...Caracter sticas de voltaje de bornes t pico 85 S loBM80 2 y BM82 2...