PIB-05
18 Feb 2015
PRODUCT INFORMATION BULLETIN
Suction Loading Station
1-7
Hydraulics
1. Remove all existing hydraulic hoses from lower water tank rear manifold to the discharge pump drive
motor
2. Mount hydraulic return manifold to mounting plate. Item 3 on drawing 048863 sheet 1 of 2.
3. Install diverter valve on pump station.
4. Install fully assembled hoses. Use drawing 048863 for hose references and locations.
5. Temporarily install partially assembled hoses with uncrimped ends.
6. Position and index uncrimped hose ends to match manifolds.
7. Mark uncrimped hose ends and remove hoses.
8. Crimp hose ends onto appropriate hoses.
9. Ensure O-rings are in place on fittings before installing.