CONTROLLERS
Please attach the controller to the product connector and only after
this plug-in controller into the power outlet. If you have a regular
connector, please connect the controller to the product to fit snugly.
If your device comes with an in-line connector, connect it so that the
male plugs go inside the female pins. After this, screw the connector so
that it’s tight. Then turn ON the controller with a toggle switch.
The controller has a temperature dial to completely adjust the heat in
1°C increment from 86°F to 158°F, displayed in Celsius from 30°C to
70°C. Sometimes we call the different temperatures “levels.”
Level 1
is 86-98°F or 30-36°C (
Lowest mode
, reveals crystals’ powers
and brings negative ions and other vital natural forces into your home
while you are seeking rest and mental clarity, great to sleep or relax).*
Level 2
is 98-110°F or 36-43°C (
Low mode
, provides a comfortable
setting for all night restful sleep to manage occasional sleeplessness,
improve absentmindedness, relieve tiredness, and maintain proper
immune function).*
Level 3
is 110-120°F or 43-49°C (
Low-medium mode
, great to
create maximum relaxation and immunity support environment,
helping to maintain healthy heart, inspired and invigorated mind,
improve the look of your skin).*
Level 4
is 120-133°F or 49-56°C (
Medium mode
, use as a part of
your dietary and healthy routine to maintain cholesterol and sugar
levels already within the normal range, alleviate the occasional blue
feeling everyone experiences from time to time).*
Level 5
is 133-145°F or 56-63°C (
Medium-High mode
, may be helpful
for a healthy lifestyle to alleviate occasional constipation, promote
sexual arousal and performance, relieve temporary water-weight gain
and mild mood changes bringing you back to normal condition).*
Level 6
is 145-158°F or 63-70°C (
High mode
, envelop yourself with the
pleasant warmth of natural crystals and gemstones. Together with exercise
patterns, it may encourage activity, contribute to spiritual balance, feeling
happy, cleansing, sweating, well-being, and better overall health).*
Level 7
is 158°F or 70°C (
The highest mode
, using extra care to create
a maximum soothing environment important for proper muscles and joints
function, optimal strength and flexibility, stress and tension reduction).
The temperatures reflect the temperature of the inner heating
elements, not the product’s surface, which can be 10-20°F lower (or
even lower than this) if the product is not covered with a thick blanket.
Usually, if the ambient temperature is around 70°F, it takes half an
hour to an hour for the product to reach the maximum level (158°F, or
70°C) if covered with a thick blanket.
Controller H-60PVA
for the products with Magnetic and PHOTON function:
1
Power ON/OFF Toggle Button
– Push it to turn the product ON/
OFF. When you turn it ON, the Display
will show
ON
. It means
that the controller is ON and ready to choose the program. If the
controller display shows
--
it means that the power is connected,
but the button has not been activated, and no functions can be
operated. Press the button harder so that lines
--
start to flicker.
2
POWER indicator
– Lights up when Power is ON.
3
Timer Control Toggle Button
– Choose one of 4 options shown on the
Display
:
1H, 4H, 8H, 0H
for 1, 4, 8, 12 hours heating session with
auto shut-off when the time expires, or you can choose
-H
NO HEATING
MODE for only Magnetism and/or PHOTON function without heating.
Press and hold for 5 seconds to turn OFF
Auto-Protection Feature
;
the display
will show
S-
. Press and hold again to reactivate this
feature; the display
will show
SA
.
4
HEATING Operation indicator
– ON when the product is heating,
OFF when the set temperature is reached.
5
Temperature, Timer, Frequency, and Program Display
– Switches
into Temperature Mode when the Temperature Dial
is rotated. The
display shows the current Celsius temperature (
30–70°C
), flashes to
the set temperature when the dial is rotated, then back again.
If the temperature is more then 122°F (50°C) for longer than 3.5
hours,
Auto-Protection Feature
will decrease it to a safe 113°F
(45°C), and the display will show
[ ]
.
In Timer mode, the display shows one of the five heatings time settings
1H, 4H, 8H, 0H,
or
-H
chosen by the Timer Control Button
. When the
heating program is over, the temperature display will show
--
,
OF,
or
ON,
indicating that Power is ON but the time set has expired. Add time to
resume heating or push the Power Button
to turn off the Controller.
In Magnetism Program mode, the display shows one of the Magnetism
program settings.
P-
(Magnetism OFF for FAR INFRARED and/or
PHOTON functions only),
PO
(manual frequency adjust mode),
P1,
P2, P3, P4, P5, P6, P7, P8, P9, PA, PC, PE, PF
(automatic Magnetism
programs). Please, check the controller user guide for details.
If Manual Frequency adjusts dial
is in active mode, the display
shows current Magnetic frequency in Hz (
1–30
pulsations per
second). Please, check the controller user guide for details.
In PHOTON Program mode, the display shows one of three PHOTON
program settings.
1P
= PHOTON ON 30 minutes.
2P
= PHOTON runs 8
program cycle (One cycle = PHOTON ON 30 minutes OFF 30 minutes).
-P
(PHOTON OFF for FAR INFRARED and/or Magnetic functions only).
The display may also show
OF
, flickering or static
--
if the Power Button
is not pressed or the connection between the controller and the
product is lost. Press Power Button
to turn ON all other controller
functions or reconnect the controller to the product tightly to resume.
6
Adjust Temperature Dial
– Use to increase or decrease heat 30–
70°C (86–158°F). The dial range is marked, indicating the desired
temperature in °F.
7
Magnetism Program Button
– Choose
P-
(Magnetism off), one of
13 automatic Program options
P1, P2, P3, P4, P5, P6, P7, P8, P9,
PA, PC, PE, PF
shown on the display
or switch to manual frequency
adjust mode
PO
. Press and hold for 3 seconds to quickly return to
P-
(Magnetism off). Please, check the controller user guide for details.
8
Adjust Magnetism Frequency Dial
– Use to increase or decrease
magnetic pulsation frequency from 1 to 30 times per second. You
can try different frequencies to find what works better for you.
9
Adjust Magnetism Frequency Dial ON Indicator
– Lights up when
Magnetism manual adjust dial is ON, frequency is chosen in manual
mode, Magnetism is ON, OFF when it stops.
10
Magnetism ON Indicator
– Lights up when Magnetic function is ON,
OFF when it stops.
11
Magnetism PROGRAM CYCLE Indicator
– Lights up when Magnetism
is auto cycled by the program, OFF when the whole program is over.
12
PHOTON Program Button
– Choose one of three PHOTON program
settings.
1P
turns ON Red Light LEDs for 30 minutes.
2P
runs an
eight cycles program (One cycle = PHOTON ON 30 minutes, OFF 30
minutes).
-P
(PHOTON OFF for FAR INFRARED and/or Magnetism
functions only). Please, check the controller user guide for details.
13
PHOTON ON Indicator
– Lights up when the Red Light LEDs are ON,
OFF when PHOTON function stops.
14
PHOTON PROGRAM CYCLE Indicator
– Lights up when Red Light is
auto cycled by program, OFF when the whole program is over.
Regular connector for
controller plug
In-line screw connector
between the mat and controller
OR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
www.MediCrystal.com
3
®
EN