Appendix C - Cabling Considerations
RJ-45 Cable
308
Mediatrix 1204
The RJ-45 cable uses two pairs of wires: one pair for transmission and the second pair for reception. It is wired
so that pins 1 & 2 are on one twisted pair and pins 3 & 6 are on a second pair according to common wiring
standards which meet the EIA/TIA T568A and T568B requirements.
Figure 69:
Straight Through Connectivity
Pin Name And Function
The following is the meaning of each pin in a RJ-45 cable.
Crossover Cable
A RJ-45 crossover cable is used when only two systems are to be connected to each other, peer to peer, at
the Ethernet Cards by “crossing over” (reversing) their respective pin contacts. An example would be
connecting two computers together to create a network. The crossover eliminates the need for a hub when
connecting two computers. A crossover cable may also be required when connecting a hub to a hub, or a
transceiver to transceiver or repeater to repeater. When connecting a hub to a transceiver, a straight through
cable is always used.
A crossover cable is sometimes called a null modem. The coloured wires at either end are put into different
pin numbers, or crossed over.
Figure 70:
Crossover Connectivity
Table 192:
Pin Name and Function
Pin #
Name
Function
1
Transmit Data Plus
The positive signal for the TD differential pair. This signal contains the serial
output data stream transmitted onto the network.
2
Transmit Data Minus
The negative signal for the TD differential pair. This contains the same
output as pin 1.
3
Receive Data Plus
The positive signal for the RD differential pair. This signal contains the serial
input data stream received from the network.
4
not connected
5
not connected
6
Receive data minus
The negative signal for the RD differential pair. This signal contains the
same input as pin 3.
7
not connected
8
not connected
Pin 1
Pin 2
Pin 3
Pin 6
Pin 1
Pin 2
Pin 3
Pin 6
Note:
This is not an IEEE supported configuration and should be used for test purposes only.
1- TX+
2- TX-
3- RC+
6- RC-
TX+ -1
TX- -2
RC+ -3
RC- -6
Summary of Contents for Mediatrix 1204
Page 6: ...Mediatrix Telecom a Division of Media5 Corporation Reference Manual...
Page 26: ...Preface About this Manual End User Technical Support xxvi Mediatrix 1204...
Page 27: ...Installation and Web Page Configuration...
Page 28: ...Page Left Intentionally Blank...
Page 50: ...Chapter 1 Installation Verifying the Installation 24 Mediatrix 1204...
Page 98: ...Chapter 4 Web Interface SIP Parameters SIP Authentication 72 Mediatrix 1204...
Page 127: ...SNMP Configuration...
Page 128: ...Page Left Intentionally Blank...
Page 162: ...Chapter 8 IP Address and Network Configuration Ethernet Connection Speed 136 Mediatrix 1204...
Page 170: ...Chapter 9 SIP Servers Presence Compositor Server 144 Mediatrix 1204...
Page 174: ...Chapter 10 DNS SRV Configuration DNS SRV Oriented Settings 148 Mediatrix 1204...
Page 196: ...Chapter 12 Configuration File Download Configuration File Example 170 Mediatrix 1204...
Page 220: ...Chapter 14 Gateway Configuration Detecting a Far End Disconnect 194 Mediatrix 1204...
Page 240: ...Chapter 16 Voice Transmissions User Gain 214 Mediatrix 1204...
Page 288: ...Chapter 23 Telephony Attributes Delayed Hot Line 262 Mediatrix 1204...
Page 294: ...Chapter 25 Quality of Service QoS VLAN 268 Mediatrix 1204...
Page 298: ...Chapter 26 Syslog Daemon Syslog Daemon Configuration 272 Mediatrix 1204...
Page 302: ...Chapter 27 Statistics RTP Statistics 276 Mediatrix 1204...
Page 319: ...Appendices...
Page 320: ...Page Left Intentionally Blank...
Page 332: ...Appendix B Standard Hardware Information Warranty 306 Mediatrix 1204...
Page 336: ...Appendix C Cabling Considerations RJ 11 Telephone Cable 310 Mediatrix 1204...
Page 372: ...Appendix E Glossary Wide Area Network WAN 346 Mediatrix 1204...
Page 390: ...Index W 364 Mediatrix 1204...