![Medialon Showmaster Go Hardware Manual Download Page 35](http://html1.mh-extra.com/html/medialon/showmaster-go/showmaster-go_hardware-manual_1760587035.webp)
Showmaster Overview
Medialon Control System
p 33 of 80
User Reference Manual
M515-2 | 2020-May
•
Interface: 10/100/1000 Mbps (1000 BaseT)
•
Protocol
: TCP/IP
•
Addressing
: Static IP or DHCP
USB Connections
•
Number: 2
•
Connector: USB slave socket
•
Interface: USB 2.0
Serial Interfaces
•
Number: 8
•
Connector: 9-pin D-type Male
•
Format: RS-232
Digital Interfaces
Isolated Inputs:
•
Number: 16
•
Type: Non-polarized, optically isolated inputs (CMOS compatible)
•
Voltage Range: 3 to 31 DC or AC RMS (40 – 10,000 Hz)
•
Isolation: 500 V channel-to-ground or channel-to-channel
•
Input Resistance: 1.8 k
Ω
in series with opto-coupler
•
Filter Response Times: Rise Time = 4.7 mS / Fall Time = 4.7 mS
•
Non-Filter Response Times: Rise Time = 10
µ
S / Fall Time = 30
µ
S
•
Connector: Sub-D 37 - type Male
Relay Outputs:
•
Number
: 16 SPDT form C Relays
•
Contact Type
: Single crossbar; Ag with Au clad
•
Rated Load AC
: 0.5 A at 125 V AC (62.5 VA max.)
•
Rated Load DC
: 1 A at 24 V DC (30 W max.)
•
Max. Switching Voltage: 125 V AC, 60 V DC
Summary of Contents for Showmaster Go
Page 1: ...Medialon Showmaster Hardware Manual User Reference...
Page 79: ......