23
© MECON GmbH BA / mag-flux HTL / EN / 21-04
TECHNICAL DATA
5.5 Medium conditions
5.4 Turbidity sensor (seperate device)
Medium, state of aggregation
Water, liquid
Minimum conductivity
>50 μS/cm
Execution
Compact flow meter with built-in pressure
sensor
Weight
see 5.7 for dimensions and weights
Display
5 inch LCD display, backlit display
(240 x 128 pixels)
Flow rate limits
0.25 ... 12 m/s
Housing material
Aluminium
Sensor materials
»
Measuring tube
»
Coil space
»
Measuring tube lining
»
Electrode material
PVC
PVC
PVC
Stainless steel
Corrosion protection class
C2 (low polluted atmosphere, dry climate)
5.6 Design / material
Type
ISO 7027 compliant
90° scattered light and 180° transmitted light
measurement pre-calibrated with formazin in
FNU units
Accuracy
±0.5 % of measured value
±1.0 % of full scale value
Fluid temperature
+5 °C ... +60 °C
Measurement range
0.1 ... 100 FNU