![Mec Titan Boom 60-S Operator'S Manual Download Page 18](http://html1.mh-extra.com/html/mec/titan-boom-60-s/titan-boom-60-s_operators-manual_1758607018.webp)
Page 14
Ttan Boom
TM
60-S - Operator’s Manual
September 2020
Secton 5 - Controls & Components
4
Circuit Breaker
Trips when there is excessive electrical load. Push to reset.
5
Overload Indicator
Light
Light ON indicates too much weight on the platform.
An audible alarm will sound and all machine function will stop.
Remove weight from the platform to restore function and continue.
6
Tilt Indicator Light
When this red light is illuminated, the machine is not level. Carefully retract the
boom, then lower the boom, before leveling the machine, or move the machine to a
firm, level surface.
7
Water & Fuel Light
Indicates if water has contaminated fuel.
8
Low Fuel Indicator
Light
When this amber light is illuminated, the fuel level is low. Refuel soon.
9
Hour Meter
Indicates total elapsed time of machine operation.
10
Outrigger Switch
Move and hold down until automatic outrigger deployment stops automatically.
Move and hold up to retract outriggers.
11
Boom Extend/Retract
Move this switch right to extend the boom.
Move this switch left to retract the boom.
12
Boom Lift/Lower
Move this switch up to lift the boom.
Move this switch down to lower the boom.
13
Platform Slide
Forward/Rearward
Move this switch right to move the platform forward along the platform support
beam.
Move this switch left to move the platform rearward along the platform support
beam.
14
Frame Level Switch
Move this switch left to manually adjust the level position of the frame to the left.
Move this switch right to manually adjust the level position of the frame to the right.
15
Platform Level
Switch
Move this switch up to manually level the rear of the platform upward.
Move this switch down to manually level the rear of the platform downward.
16
Platform Rotate
Switch
Move this switch left to rotate the platform clockwise.
Move this switch right to rotate the platform counterclockwise.
The Platform Rotate function will stop when the platform reaches its detent center
position. To continue to rotate the platform, return the switch to the neutral position,
then push the switch to rotate the platform in the desired direction.
17
Selector Switch
Platform
Select to operate from the platform control panel.
Base
Select to operate from the base control panel.
Off
Select to stop operation from either control panel.
18
Start/Stop Switch
Push switch to the right until engine starts then release switch.
19
Glow Plug Light
The light will turn on when the Kubota ECU determines it necessary to activate glow
plugs before starting the engine.
20
Starter Time-out
Indicator / Check
Engine Light
When this red light is illuminated, the starter circuit is temporarily disabled. The
starter circuit times out if the starter is run continuously for 15 seconds without the
engine starting. The starter functions resets after 30 seconds.
When blinking, functions as an Engine ECU Fault Code indicator.