Measurement Technology NW
LCI-90 Operator Manual
Page 64
14.0 Appendix F – LCI-90 Specifications
LCI-90
PHYSICAL/POWER
Std/Option
Temp.
-40
˚
C to 75
˚
C
Std
Environmental
NEMA 4X front panel
Std
NEMA 1 rear enclosure
Std
Dimensions
7.6” wide x 5.7” high x 3.7-4.8” deep (per options)
Std
Cut out: 7.15” wide x 5.25 high
Std
Weight
3.4 pounds
Std
Materials
Stainless Steel 316 front panel
Std
Polycarbonate display window
Std
Urethane front panel gasket
Std
Power
18-36 VDC, 0.5 A typical, 0.75 A maximum
Std
Heat Output
8 Watts typical
Std
LCI-90
DISPLAY
Std/Option
Type
Graphic electro-luminescent, 320 x 240 pixels
Std
View Angle
160 degrees
Std
Viewing Area
4.7” wide x 3.6” high
Std
Brightness
High brightness – 50 cd/m2
Std
Ultra high brightness – 340 cd/m2
HT
Contrast
Fixed
Std
Adjustable
HT
Characters
6 at top center, 4 at lower left, 5 at lower right
Std
LCI-90
COUNT SENSOR INTERFACE
Std/Option
Type
Inductive proximity, quadrature, PNP, NPN, 2 or 3 wire
Std
Quadrature encoder, CMOS or TTL
Std
Frequency
0.05 Hz to 10 kHz
Std
Excitation
12 VDC, 250 mA (total for device)
Std
5 VDC, 250 mA (total for device)
Std
Thresholds
3.4 V Low-High transition, 2.3 V High-Low transition
Std