Measurement Technology NW
LCI-90 Operator Manual
Page 12
4.0
Options and Wiring Diagrams
The LCI-90 can be configured for a wide range of signal input and output functions. Each
of these functions requires the instrument to have the correct menu settings (Section 5.0),
DIP switch settings (Appendix B), signal and power wiring, and in some cases, optional I/O
modules installed. The wiring diagrams are given in this Section; the optional I/O modules
are listed in Appendix D. The table below gives of a summary of the LCI-90 functions,
referenced to their associated menu and DIP switch numbers, required hardware options,
and section of this manual covering the wiring termination.
Function
Menu Number
DIP Switch #
Std/Option #
Wiring – Manual
Section
DC Power
N/A
N/A
Std
4.1.1
Analog Input
Direct 4-20 mA
4.2
SW1
Std
4.1.2
Analog Input
Direct DC
Voltage
4.2
SW1
Std
4.1.2
Analog Input
Isolated
4.2
SW1
21,22,23
4.1.2
Payout Sensor
Input
2.0
SW4
Std
4.1.3
Alarm Output
4.4
SW2
01,02,03,04
4.1.4
Analog Output
Direct 4-20 Ma
4.3
N/A
30
4.1.5
Analog Output
Direct DC
Voltage
4.3
N/A
31
4.1.5
Analog Output
Isolated
4.2
N/A
32, 33
4.1.5
Serial Comm.
RS232, Network
4.5
N/A
10
4.1.6
Serial Comm.
RS485, Network
4.5
SW3
11
4.1.6
Serial Comm.
RS232, Auxiliary
4.5
N/A
Std
4.1.6
Figure 4.1 – Identification of hardware options, DIP switches and manual sections by
function