5.5
Tension Tare
To perform a tension tare, press
CALB
to display the main
2.0 CALIBRATION
menu,
shown below. Select Item 2 and press
ENT
to activate the edit keys. Press either
INCR
or
DECR
to toggle between
ON
and
OFF
. Press
ENT
to accept the selection. When Tension
Tare is turned
ON
, the tension input
at that moment
will be saved and subtracted from all
future displayed values. To warn the user that the displayed value is not the real tension
(which could be much higher!), an asterisk (*) is displayed after the TENSION label. When
Tension Tare is turned
OFF
the tare value (and the asterisk) are removed, and the actual
tension is again displayed.
2.0 CALIBRATION
1
TENSION (THREE METHODS)
>
2
TENSION TARE
ON
3
SHUNT CAL
OFF
4
WRAP ANGLE
120 DEG
5
PAYOUT SCALE
2.800 P/FT
6
PAYOUT PRESET
150 FT
5.5.1 Tension Tare
The tare function is a way to zero a small displayed tension value. Care should be
taken when using the tare function as the displayed value does not reflect actual line
tension but rather line tension minus the tare value. Any alarms that are set to
monitor the tension input will be triggered by the actual line tension value, not the
displayed value. The tare function can be deactivated at any time, returning the unit
to its normal tension display.