Controls
On/Off Switch: Spring loaded trigger switch under handle
Function Select Switch (Three position): P – Power Mode; R – Radio Mode; G - Generator Mode
Sensitivity Control
Depth Button: Push button for live display of depth - DXL3 only
Audio Indication
Removable and user replaceable loudspeaker module
Visual Indication
Multi-segment Liquid Crystal Display indicating:
Signal Strength; Mode selected; Battery Condition;
Depth Measurement (in Generator Mode) - DXL3 only
Construction
Case moulded from high impact plastic. Designed to withstand 1m (3’3”) drop onto a hard surface
Weight (including batteries)
2.9kg (6 pounds 6 ounces)
Dimensions
720mm x 270mm x 63mm (28.3” x 10.6” x 2.4”)
Performance
Locate Accuracy: better than 10% of depth
Depth Accuracy: ±5% @ 1m (3’3”) - DXL3 only
Depth Measurement Range: Line 0.2m to 3m (8” to 10’)
Depth Resolution: Line 0.05m
Depth Measurement Range: Sonde 0.85m to 4.5m (2’9” to 15’) - depending on Sonde type
Depth Resolution: Sonde 0.15m
Battery Type
Internal 8 x ‘AA’ (LR6) cells (either alkaline non-rechargeable or NiMH rechargeable)
Battery Life
40 hours intermittent use at 20ºC (68ºF) using alkaline cells
IP Rating
65
Note
Performance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields.
Specification may be subject to change.
All C.Scope Locators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014/30/EU.
Compliance has been demonstrated by testing representative samples to the relevant harmonised standards.
All C.Scope Locators comply with the RoHS directive, 2011/65/EU.
CXL3 and DXL3 Locators Technical Specifications
42