background image

www.procontechnology.com.au

 

 

Phone: (03) 98306288

 

 

 

 

External Earthing Mobile Applications - Connect an earth wire (preferably solid green 
or green with yellow stripe) from the external earth connection (Chassis GND) on the 
rear of the inverter to the chassis of the vehicle or ground wires on a boat. 

 

 

 

CHASSIS  CONNECTION 
 

 

OPERATION

 

Caution:

 

 

Never connect the AC output of the inverter to normal fixed building wiring or any 
wiring connected to the mains grid. Normally AC wiring contains a MEN link - this 
neutral to earth link can damage the inverter and compromise safety.

 

 

This inverter is designed for direct connection to appliances however extension 
leads and power boards can be used for low wattage appliances.

 

 

PROTECTION  FEATURES

 

Meanwell inverters include sophisticated circuitry that monitors the operation of the 
inverter and turns the inverter off if a problem is detected. A fault light will illuminate 
and an audible alarm may be heard if this occurs. This prevents damage to the inverter, 
batteries and/or appliance being powered. 

 

 

Low Battery - This feature will sound an alarm when the battery system powering the 
inverter is low. It is recommended that the appliance is turned off, then the inverter is 
turned off and the batteries recharged before switching on again. 

 

If the appliance is allowed to continue to run, the inverter will turn off when the 
batteries are very low to prevent over discharging the batteries or damaging the 
inverter. This will cause a sudden disruption of power to the appliance that may cause 
problems for some devices. e.g. computers that need to be shut down properly. 

 

 

High Battery - This feature will shut down the inverter when the battery system is too 
high in voltage. This prevents damage to the inverter.  An over voltage condition could 
occur if the wrong battery system is used or a fault occurs whilst attempting to charge 
the battery when it is connected to the inverter. 

 

 

Overload - This feature will turn the inverter off when the total load connected to the 
inverter exceeds the inverter's rating (see 

"

Determining suitable loads/appliances

"

). 

Summary of Contents for A301-1K0

Page 1: ...A302 1K0 1000 Watts A301 A302 1K7 1500 Watts A301 A302 2K5 2500 Watts A301 12VDC input A302 24VDC input 230VAC output Don t disassemble Keep away from moisture Keep away from fire heat Don t stack in...

Page 2: ...ockets Twin power outlet sockets Temperature controlled automatic cooling fan ON OFF remote control optional SPECIFICATIONS Part No A301 A302 1K0 A301 A302 1K7 A301 A302 2K5 Input Voltage 12V 24V Batt...

Page 3: ...300 200 200 200 100 100 100 0 0 0 100 100 100 200 200 200 300 300 300 400 400 400 MAINS POWER SINEWAVE MODIFIED SINE WAVE TRUE SINE WAVE Logically it follows that the process used in a TSW inverter is...

Page 4: ...he inverter Part No A301 A302 1K0 A301 A302 1K7 POWER FAULT LIGHTS AC OUTPUT SOCKETS FAN DC CABLE ENTRY POWERON SWITCH FRONT REAR Supplied Operating instructions Negative Black DC connectionleadfitted...

Page 5: ...e inverter a suitable 12V or 24V DC power supply is required This can be vehicle or caravan batteries a portable power pack or battery bank joined in series and or parallel to produce 12V or 24V DC Fo...

Page 6: ...ell inverters are designed FOR INDEPENDENT USE ONLY The inverter cannot be connected to household wiring whether the building is connected to the electricity grid or not The 1000W and 1500W inverters...

Page 7: ...run close together to reduce cable inductance The cables should also be protected from any damage Any connections should be made securely using the proper hardware Procon Technology recommends the use...

Page 8: ...d if this occurs This prevents damage to the inverter batteries and or appliance being powered Low Battery This feature will sound an alarm when the battery system powering the inverter is low It is r...

Page 9: ...efore resuming operation If possible reduce the load on the inverter and improve ventilation DETERMINING SUITABLE LOADS APPLIANCES The inverter is fitted with 2 approved AS NZS Australian socket outle...

Page 10: ...rter will not run my appliance even though the appliance label indicates that it draws less power than the size of the inverter A Electrical appliances can be divided into three groups by the way they...

Page 11: ...GND the inverter see the section on Earthing Q Can I run fluorescent lighting from myinverter A Most portable fluorescent work lamps should operate fine on an inverter even though they may be slow to...

Page 12: ...t of the motor and allow an appliance to be used with an inverter where otherwise it would cause it to overload Q Can I run a laptop computer A Most laptop notebook computer AC power adapters work per...

Page 13: ...AIMER All specifications are subject to change without notice Any circuit diagrams or assembly diagrams provided with equipment are for reference purposes only Procon Technology makes no representatio...

Reviews: