background image

www.procontechnology.com.au

 

 

Phone: (03) 98306288

 

 

CONNECTIONS / CONTROLS & ACCESSORIES

 

After unpacking your inverter take a moment to check that you have the correct model 
(A301 = 12V, A302 = 24V) and all the correct accessories are included. Familiarize 
yourself with the connections and the controls on the inverter. 

 

Part No. A301/A302-1K0 & A301/A302-1K7

 

 

POWER & FAULT    

LIGHTS 

   

                AC    OUTPUT SOCKETS 

               

FAN 

             

DC CABLE ENTRY 

 

POWER ON 

                         SWITCH 

FRONT

 

 

     

REAR

 

 

Supplied: 

 

Operating instructions 

 

Negative (Black) DC connection lead fitted with ring terminal 

 

Positive (Red) DC connection lead fitted with ring terminal 

 
 

Part No. A301/A302-2K5

 

 
 

 
 
 
 
 

 

 
 
 

 

 

 
 

 

 
 

            FRONT 

                REAR

 

 

Supplied: 

 

Operating instructions 

POWER ON 
SWITCH

 

AC    OUTPUT SOCKETS

 

POWER & FAULT 

LIGHTS

 

VOLTS INDICATOR 

 

AMPS INDICATOR 

 

- DC TERMINAL (BLACK)

 

FAN 

 

+ DC TERMINAL (RED) 

 

CHASSIS 

GROUND

 

CHASSIS 

GROUND

 

Summary of Contents for A301-1K0

Page 1: ...A302 1K0 1000 Watts A301 A302 1K7 1500 Watts A301 A302 2K5 2500 Watts A301 12VDC input A302 24VDC input 230VAC output Don t disassemble Keep away from moisture Keep away from fire heat Don t stack in...

Page 2: ...ockets Twin power outlet sockets Temperature controlled automatic cooling fan ON OFF remote control optional SPECIFICATIONS Part No A301 A302 1K0 A301 A302 1K7 A301 A302 2K5 Input Voltage 12V 24V Batt...

Page 3: ...300 200 200 200 100 100 100 0 0 0 100 100 100 200 200 200 300 300 300 400 400 400 MAINS POWER SINEWAVE MODIFIED SINE WAVE TRUE SINE WAVE Logically it follows that the process used in a TSW inverter is...

Page 4: ...he inverter Part No A301 A302 1K0 A301 A302 1K7 POWER FAULT LIGHTS AC OUTPUT SOCKETS FAN DC CABLE ENTRY POWERON SWITCH FRONT REAR Supplied Operating instructions Negative Black DC connectionleadfitted...

Page 5: ...e inverter a suitable 12V or 24V DC power supply is required This can be vehicle or caravan batteries a portable power pack or battery bank joined in series and or parallel to produce 12V or 24V DC Fo...

Page 6: ...ell inverters are designed FOR INDEPENDENT USE ONLY The inverter cannot be connected to household wiring whether the building is connected to the electricity grid or not The 1000W and 1500W inverters...

Page 7: ...run close together to reduce cable inductance The cables should also be protected from any damage Any connections should be made securely using the proper hardware Procon Technology recommends the use...

Page 8: ...d if this occurs This prevents damage to the inverter batteries and or appliance being powered Low Battery This feature will sound an alarm when the battery system powering the inverter is low It is r...

Page 9: ...efore resuming operation If possible reduce the load on the inverter and improve ventilation DETERMINING SUITABLE LOADS APPLIANCES The inverter is fitted with 2 approved AS NZS Australian socket outle...

Page 10: ...rter will not run my appliance even though the appliance label indicates that it draws less power than the size of the inverter A Electrical appliances can be divided into three groups by the way they...

Page 11: ...GND the inverter see the section on Earthing Q Can I run fluorescent lighting from myinverter A Most portable fluorescent work lamps should operate fine on an inverter even though they may be slow to...

Page 12: ...t of the motor and allow an appliance to be used with an inverter where otherwise it would cause it to overload Q Can I run a laptop computer A Most laptop notebook computer AC power adapters work per...

Page 13: ...AIMER All specifications are subject to change without notice Any circuit diagrams or assembly diagrams provided with equipment are for reference purposes only Procon Technology makes no representatio...

Reviews: