63
Bit 6 STGS:2/3 Stage Charge Setting
= 3 stage charge(default, CURVE_CV and CURVE_FV)
0
1= 2 stage charge (only CURVE_CV)
Bit 7 CUVE:
Charge Curve Function Enable
0=
disabled power supply mode(default)
,
1=
enabled charger mode
,
High byte:
Bit 0 CCTOE:
Constant Current Stage Timeout Indication Enable
=
0
disable (default)
1=
enabled
Bit 1 CVTOE:
Constant Voltage Stage Timeout Indication Enable
=
0
disable (default)
1=
enabled
Bit 2 FTTOE:
Float Voltage Stage Timeout Indication Enable
0=
disable (default)
1=
enabled
Note: Unsupported settings displays with "0"
◎
CHG_STATUS(0x00B8, only for charger)
:
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
High byte
Low byte
NTCER
CVM
BTNC
FVM
FVTOF
CVTOF
-
CCTOF
-
-
-
-
-
CCM
-
FULLM
Low byte
Bit 0 FULLM:
Fully Charged Mode Status
0=
NOT fully charged
1=
fully charged
Bit 1 CCM:
Constant Current Mode Status
0=
the charger NOT in constant current mode
1=
the charger in constant current mode
Bit 2 CVM:
Constant Voltage Mode Status
0=
the charger NOT in constant voltage mode
1=
the charger in constant voltage mode
6
64
Bit 3 FVM:Float Mode Status
0=the charger NOT in float mode
1=the charger in float mode
High byte:
Bit 2 NTCER:Temperature Compensation Status
0=NO short-circuit in the circuitry of temperature compensation
1=the circuitry of temperature compensation has short-circuited
Bit 3 BTNC:Battery Detection
0=battery detected
1=No battery detected
Bit 5 CCTOF:Time Out Flag of Constant Current Mode
0=NO time out in constant current mode
1=constant current mode timed out
Bit 6 CVTOF:Time Out Flag of Constant Voltage Mode
0=NO time out in constant voltage mode
1=constant voltage mode timed out
Bit 7 FTTOF:Time Out Flag of Float Mode
0=NO time out in float mode
1=float mode timed out
Note: Unsupported settings displays with "0"
6