31
5.9
Auxiliary Output
●
Built-in 12V/0.5A auxiliary output.
Figure
5 8
-
+12V-AUX to GND-AUX
12Vdc
5.10
Charging (Only 55V model has built-in charging function,
the other models with higher output voltage need to
cooperate with BMS for charging)
●
HEP-2300
adopts both 2 and 3 stage charging curves for selection. 2
stage is for easy and fast charging. 3 stage will go into float mode after
the battery is fully charged. Users can choose between 2 or 3 stage
according to the demand.
5.8
DC-OK Signal
●
Built-in DC output voltage detection circuit.
●
Maximum output current 10mA.
Figure
5 7
-
DC-OK to GND-AUX
Condition
4.5 – 5.5V
DC OK
-0.5 – 2.5V
Abnormal DC
PIN9 & 10 GND-AUX
PIN5
DC OK
& 6
CN11
5
PIN9 & 10 GND-AUX
PIN7
+12V-AUX
& 8
CN11
32
Explanation of 2 stage charging curve
Initial stage (battery analysis)
:
Charger will detect and determine whether the battery is properly
connected or it is already fully charged.
Stage 1 (Constant current)
:
Maximum constant current is applied for fast charging, until the
voltage of battery reaches to boost voltage.
Stage 2 (Constant voltage)
:
In this stage, charger applies a constant voltage on the battery.
Charging current decreases gradually and then shuts down when
charging current
to 10% of rated current.
drops
Suitable for lead-acid batteries, such as flooded water type, Gel
colloid type, AGM adsorption glass fiber and lithium batteries, such
,
as lithium iron, lithium manganese, ternary lithium.
-
-
1
2
3
*
State
Constant Current
V
boost
HEP-2300-55
40A
57.6V
Charge
Current
stage 1
Constant
Current
Constant
Voltage
stage 2
Battery Full
Start
Charge
Voltage
100%
10%
V
boost
Orange
Green
Color of LED
Loading Indicator
5
In the initial stage of charging, the charger charges the battery
with the maximum current. After a period of time (depending on
the battery capacity), the charging current decreases gradually.
When the charging current drops to 10% of the rated current. LED
indicator lights up in green, indicating that the charging process
is complete.
5.
.1
10
2 stage charging