53
byte2:
Bit :3 TEMPERATURE_1 Factor:
0
The Factor of internal ambient temperature
0x =internal ambient temperature relevant commands not supported
0
0x4=0.001
0x5=0.01
0x6=0.1
0x7=1.0
0x8=10
0x9=100
Bit 4:7 CURVE_TIMEOUT Factor:
The Factor of CC/CV/Float timeout
0x =
0
CURVE_TIMEOUT relevant commands not supported
0x4=0.001
0x5=0.01
0x6=0.1
0x7=1.0
0x8=10
0x9=100
byte3:
Bit 0:3 IIN Factor:
The Factor of AC input current
0x =
0
AC input current relevant commands not supported
0x4=0.001
0x5=0.01
0x6=0.1
0x7=1.0
0x8=10
0x9=100
6
54
◎
SYSTEM_STATUS (0x00C )
1
:
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Low byte
-
-
-
EEPER
INITIA-
LSTATE
ADL_ON
DC_OK
-
Low byte:
Bit 1 DC_OK:Secondary DD output voltage status
=Secondary DD output voltage status TOO LOW
0
1=Secondary DD output voltage status NORMAL
Bit 4 ADL_ON:Active dummy load control status
=Active dummy load off/function not supported
0
1=Active dummy load on
Bit 5 INITIAL_STATE:Device initialized status
=In initialization status
0
1=NOT in initialization status
Bit 6 EEPER:EEPROM data access error
=EEPROM data access normal
0
1=EEPROM data access error
Note: Unsupported settings displays with "0"
6