10
14-DISPLAYS
IGNITION
FEED SCREW ACTIVATION (FIRST IGNITION OR AFTER HOPPER EMPTYING)
Prior to first product ignition, it is necessary to load the fuel and preload the pellets inside the feed screw for loading the fuel in the brazier.
To do this, simply press and hold the
key for 10 seconds and the “feed screw
loading” will activate.
The button turns red until the phase ends or is interrupted.
To activate this function, the product must be OFF and COLD (the key
must be white and NOT flashing).
The display shows the feed screw icon and the countdown starting from the
maximum number of seconds provided for the preload cycle (e.g. 120 seconds).
The moment you start to see the pellet drop into the brazier, you must
stop loading by pressing the key.
Ignition must start with an empty brazier and not with a preload.
RED ICON
Display upon ignition
Display at first ignition:
• Press and hold the key for at least 2” (after having awakened the display), the product switches to on and the key flashes until
the ignition phase has been completed. The crown appears and moves to the icon at the top, relative to general operation
• The room temperature reading appears
• Upon first ignition, only three icons are enabled (general operation/room temperature/system temperature) the others are
displayed but not enabled
• If you later decide to enable the puffer or storage tank outputs, the other icons will also be enabled (see “User menu” chap.).
• The icon for the stove appears as well as the power request from the various radiators/puffers/storage/DHW.