Maintenance and cleaning
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
8.2.3.
Cleaning of the heat exchanger
NASIK:
Remove the ventilation grille (2) by unscrewing the two black self-
tapping screws (1) which can be seen between the first and the second
profile of the grille, taking care not to damage the paint. Remove the
four M5 screws (3) and remove the cast iron exchanger (4). Clean any
soot off the exchanger and remove any incrustations from the surface.
Use a vacuum cleaner to remove the ash that may have built up over
the refractory elements. Replace the seal (5) with a new one and
reassemble everything, performing the above tasks in the reverse
order.
KAMA:
Remove the two screws (1) securing the grille in place, remove the
ventilation grille (2) with the help of a hook and taking care not to
damage the paint. Remove the four M5 screws (3) and remove the cast
iron exchanger (4). Clean any soot off the exchanger and remove any
incrustations from the surface. Use a vacuum cleaner to remove the
ash that may have built up over the refractory elements. Replace the
seal (5) with a new one and reassemble everything, performing the
above tasks in the reverse order
8.2.4.
Cleaning of smoke duct and general checks
Clean the smoke discharge system, especially in the area of the tee
connectors, curves and any horizontal stretches of pipe.
For information on cleaning the flue pipe, contact a professional
chimney sweep.
Check the seal of the ceramic fibre gaskets on the door of the stove. If
necessary, order new gaskets from the retailer for replacement or
contact an authorized service centre to carry out this work.
ATTENTION:
The frequency with which the smoke discharge
system is cleaned should be determined based on the
type of use that is made of the stove and the type of
installation.
MCZ suggests relying on an authorized service centre
for end-of-season cleaning and maintenance, who
will carry out all of the previously mentioned work
and make a general check of the stove's components.
8.2.5.
Other checks
All seal gaskets installed on components subject to maintenance
(smoke intake fan, inspection panels, etc.) must be replaced when
those parts are removed for maintenance. Check the seal of the
gaskets on the fire door. If necessary, contact an authorized service
centre to have them replaced
MCZ suggests relying on an authorized service centre
for end-of-season cleaning and maintenance, who
will carry out all of the previously mentioned work
and make a general check of the stove's components.
Nasik exchanger
Kama grille
Scambiatore Kama