7.1.
ALARM SIGNALLING
If there is an operating anomaly, the stove goes into alarm shutdown
mode and informs the user of the type of problem that has occurred via
a 3-figure code displayed on the rear emergency panel.
The alarm is permanently signalled by the corresponding 3-figure code,
by a flashing red light on the emergency panel, and, for the first ten
minutes of the alarm, by a periodic acoustic signal, which can be
interrupted by turning the unit off with the remote control. To exit
alarm conditions and restore its normal operation, read the instructions
in the next two paragraphs.
The following table summarizes the possible alarms which the stove
may signal and corresponding code which appears on the emergency
panel.
MESSAGE ON
DISPLAY
TYPE OF PROBLEM
SOLUTION
A01
Fire fails to ignite
Check the level of pellets in the hopper.
Check that the grate is properly inserted in its housing
and does not have any obvious unburnt incrustations;
Check whether the ignition plug heats.
A02
Fire extinguishes abnormally
This is because the fire goes out due to lack of fuel
(hopper empty) or by an excess of pellets in the grate
which suffocates the flame.
A03
Pellet hopper temperature exceeds required
safety limit.
Overheating of the stove body
The air fan may be damaged or stopped, and is not
able to cool the structure. wait until the structure is cool
before restarting the stove.
A04
The temperature of the smoke discharge has
exceeded pre-set safety limits
The stove will shut off automatically. Let the stove cool
off for a few minutes, then re-light it.
Check smoke release and position of the temperature
probe.
Check the type of pellet being used.
A05
The pressure switch has tripped due to
obstruction of the flue pipe caused by foreign
objects, soot/ashes or atmospheric agents
(wind, snow, etc.)
Check and clean the WHOLE flue system
Protect the outlet from the wind.
A06
The smoke extractor is not able to provide the
primary air required for combustion.
Draught difficulties or clogging of grate.
Check whether the grate is clogged by incrustation and
clean as required.
Check and clean flue system as necessary
A08
The smoke extractor is not running.
Check that the smoke fan compartment is clean and if it
is dirt that is blocking it.
Smoke fan failure. Replacement