Maintenance and cleaning
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
ATTENTION!
Do not use alcohol. Do not spray the detergent
directly onto the glass. MCZ will not be held liable for
damage to the silkscreen printing of the glass if these
instructions are disregarded. Do not clean the painted
parts.
8.1.4.
Cleaning of the air filter
At the lower part of the stove, where there is the inlet pipe for
combustion air Ø 5 cm, at the time of installation of the stove a metal
mesh air filter must be inserted to prevent dirt from getting into the
motor body and internal sensor.
It is advisable to check every 15/20 days whether the filter is clean.
Remove lint or any other material which may have been trapped by the
filter.
Checking and cleaning will be required more frequently if there are pets
in the home.
For cleaning, just turn the knob that holds the filter on the air intake
pipe and remove the filter by turning in the direction indicated by the
arrow. Clean it with a brush, damp cloth or compressed air.
The filter is made of metallic mesh. It is soft and
malleable to the touch. Therefore, when cleaning it,
be careful not to crush it or damage it in any other
way. If it is broken it must be replaced
ATTENTION!
Never operate the stove without the air filter. MCZ
shall not be held liable for damage to internal
components if this instruction is not followed.
8.2.
PERIODIC CLEANING
8.2.1.
Cleaning of the heat exchanger
Halfway through the winter,
but especially in the spring,
you will
need to clean the air spaces where discharge smoke passes.
This cleaning
must
be done in order to remove all combustion residues
before time and humidity let them harden and make them difficult to
remove.
8.2.2.
Cleaning the smoke discharge duct
When the appliance is cold, open the fire door and clean the two smoke
discharge ducts, situated above the refractory rear back panel. To do
so, insert a bottle brush (preferably iron) and scrape the walls of the
fire box so that all the ash falls into the part below. Remove the rear
protection panel of the stove by unscrewing the 7 screws securing it to
the structure. Loosen the bolts and open the inspection panel located
to the left of the smoke exhaust fan. Use a small brush to scrape all the
openings and the walls of the conduit so that any ash falls off. Remove
all the ash that may have built up on the bottom of the chamber using
a vacuum cleaner.
Put everything back in place by performing the above steps in reverse
order.