PELLET STOVES
Chapter 5
INSTALLATION AND USE MANUAL
page
42
Menu structure
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
Esc Set
< Settings >
Mode:Auto Menu
Temp:22°C Fan:A
Esc Set
< Settings >
21.0°C 21.04
OFF
Esc OFF Set
Thermostat
Esc It Set
< Language >
Esc OFF Ok
Thermostat
Esc On Ok
Thermostat
Esc On Ok
Thermostat
5.4.6.1.
Operating mode with external thermostat
In the SETTINGS - THERMOSTAT MENU select ON and exit the menu;
at this point, by selecting the AUTO operating mode (para 2.2) in the
place of the room temperature the word OFF will appear as the external
thermostat takes control of the stove. (contact open = temperature
achieved = stove on minimum; contact close = temperature not
achieved = stove on maximum)
In the condition of temperature achieved (thermostat contact open) the
stove does not shutdown but automatically modulates the flame to
minimum power; when the temperature is not achieved (thermostat
contact closed) the stove automatically modulates the flame to
maximum power.
Summary of Contents for KAIKA
Page 1: ...USE AND MAINTENANCE MANUAL...