PELLET STOVES
Chapter 5
INSTALLATION AND USE MANUAL
page
41
Menu structure
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
SONDA
POS.14
CAVO TERMOSTATO
AMBIENTE
5.4.6.
Connection to a room thermostat
The room thermostat is not included with the stove
and it must be installed by a specialised technician.
WARNING!
The electrical wires must not be in contact with the
hot parts of the stove.
The stove can also be connected to a room thermostat. The procedure
to follow for the connection of the external thermostat is the following:
Connect the two wires of the cable which come from the room
temperature to the two free terminals of the connector
(
position
14
wiring diagram chap.7). To do this it is
necessary to:
o
unscrew the protective cap of the probe
o
Pass the two wires through the protective cap and
insert them into the hole together with the probe.
o
Pull the two wires to carry out connection to the board
corresponding to terminal 14 (see chap.7)
o
Close the protective cap again.
PROBE
THERMOSTAT CABLE
Summary of Contents for KAIKA