1.3.  

GUARANTEE TERMS 

MCZ guarantees the product, 

with the exception of 

parts subject to normal wear specified 

below, for 

two years from the date of purchase, provided that 

proof of purchase is supplied in a document specifying 

the name of the retailer and the date the sale was 

made and that the completed guarantee certificate 

was sent within 8 days of said purchase. The product 

must also be installed and tested by a specialised 

fitter and in accordance with the detailed instructions 

provided in the instruction manual that accompanies 

the product. 
The guarantee covers the replacement or free repair 

of parts recognised as being faulty at source 

due to manufacturing defects. 

1.3.1.  

Guarantee limits 

The aforementioned guarantee does not cover 

electrical parts for which the guarantee period is one 

year from the date of purchase of the product, proven 

as indicated above. The guarantee does not cover 

parts subject to normal wear, such as 

seals, glazing 

and all removable parts of the combustion 

chamber. 

Parts replaced will be guaranteed for the remaining 

guarantee cover period, starting from the original 

date of purchase of the product. 
 

 

The glazing, in particular, is 

guaranteed until an authorised MCZ 

fitter certifies that it was perfectly 

intact at the time that installation 

was completed.

 

 

1.3.2.  

Exclusions  

The guarantee does not cover any parts found 

to be faulty due to negligence, inappropriate 

use, incorrect maintenance or installation not 

performed in compliance with MCZ's 

instructions (see relevant chapters in this use 

manual). 

MCZ cannot be held liable for any damage which may 

- either directly or indirectly - be caused to persons, 

animals or property ensuing from failure to observe all 

the instructions provided in the instruction manual 

and, specifically, the warnings regarding installation, 

use and maintenance of the device. 
Please contact your retailer and/ or local importer in 

the event of product failure. 
Damage caused by transport and/ or handling are not 

covered by the guarantee. 

Refer solely to the manual provided for information 

about product installation and use. 
The guarantee does not cover damage caused by 

tampering with the device, atmospheric agents, 

natural disasters, electrical discharges, fires or faults 

in the electrical and plumbing system. The guarantee 

also excludes damage caused by failure to perform 

maintenance or by maintenance performed incorrectly 

and not in compliance with the Manufacturer's 

instructions. 
 

SERVICE CALL 
Service calls must be made to the 

retailer, who will forward the call to 

the MCZ technical support 

department.

 

 
MCZ cannot be held liable if the 

product and any of its accessories are 

used incorrectly or modified without 

authorisation. 

Only original MCZ spare parts must be 

used for replacements. 

 

 
 

1.4.  

IMPORTANT INFORMATION FOR 

CORRECT DISPOSAL OF THE PRODUCT 

IN ACCORDANCE WITH EC DIRECTIVE 

2002/96/EC 

.

 

 

At the end of its working life, the product must not be 

disposed of as urban waste. 

It must be taken to a special local authority 

differentiated waste collection centre or to a dealer 

providing this service. 

Disposing of a appliance separately avoids possible 

negative consequences for the environment and 

health deriving from inappropriate disposal and 

enables the constituent materials to be recovered to 

obtain significant savings in energy and resources.  

As a reminder of the need to dispose of appliances 

separately, the product is marked with a crossed-out 

wheeled dustbin. 

Summary of Contents for FORMA WOOD 75 DX-SX

Page 1: ...8901161300 USE AND INSTALLATION MANUAL EN...

Page 2: ...ion 13 3 3 Dimensions of the Forma Wood T95 14 3 4 Technical specifications 15 4 INSTALLATION AND ASSEMBLY 16 4 1 PREPARATION AND UNPACKING 16 4 2 OPERATING MODE SELECTION 17 4 2 1 Natural convection...

Page 3: ...nts Technical dept All rights reserved by MCZ Group S p A Reproduction prohibited 6 1 1 Cleaning the glazing 28 6 1 2 Ash removal 28 6 1 3 Cleaning refractory walls ALUTEC 28 6 2 CLEANING UNDER THE RE...

Page 4: ...is document the Manufacturer reserves the right to make any changes without notice All reproduction including partial of this manual without the Manufacturer s authorisation is strictly prohibited Car...

Page 5: ...liability for incorrect use Tampering of any nature or replacement of spare parts with non original parts may endanger the operator MCZ bears no civil or criminal liability for tampering or use of no...

Page 6: ...se manual MCZ cannot be held liable for any damage which may either directly or indirectly be caused to persons animals or property ensuing from failure to observe all the instructions provided in the...

Page 7: ...that present a fire hazard for example garages timber storerooms or warehouses for flammable materials The provisions of all the applicable standards in force must be observed in all circumstances Ins...

Page 8: ...rough hole with a minimum free cross section of 360 cm in the external wall near the closed fireplace 22 cm diameter or 20x18 cm rectangular hole protected by a grille on the inside and on the outside...

Page 9: ...event obstructions nor too short to prevent smoke leakage If metal connections are used it is essential that they be insulated with suitable material such as ceramic fibre to prevent damage to walls a...

Page 10: ...inspect from an airtight flap IMPORTANT If you have doubts about the performance of your flue pipe or if the dimensions of the pipe differ from the recommended values it is highly advisable to have a...

Page 11: ...ain snow and any foreign bodies from penetrating the flue pipe Be positioned so as to ensure adequate dispersion of smoke and in all cases outside the reflux area in which back pressures are likely to...

Page 12: ...roup S p A Reproduction prohibited 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 3 1 Dimensions of the Forma Wood 75 rh lh fig shows lh version 428 258 244 830 750 rivestimento 705 porta 1389 580 rivestim...

Page 13: ...ts reserved by MCZ Group S p A Reproduction prohibited 3 2 Dimensions of the Forma Wood 95 rh lh fig shows lh version 509 72 99 455 porta 467 porta 583 503 rivestimento 1025 900 porta 945 rivestimento...

Page 14: ...s Technical dept All rights reserved by MCZ Group S p A Reproduction prohibited 3 3 Dimensions of the Forma Wood T95 1067 1025 porta 1288 47 137 1026 rivestimento MIN 33 MAX 60 489 rivestimento 514 5...

Page 15: ...smoke 13 O2 0 16 Smoke flow rate 20 1 g s Flue Pipe Up to 5 m 30x30 cm diameter 30 Over 5 m 25x25 cm diameter 25 Notes Intermittent combustion appliance These data may vary according to the type of fu...

Page 16: ...uring transport The carrier or retailer must be informed immediately of any damage If the closed fireplace is installed in a place that is difficult to access the weight can be lightened by removing t...

Page 17: ...esponsibility of the end user in compliance with the applicable laws in force 4 2 OPERATING MODE SELECTION IMPORTANT Decide which system to use before installing the appliance The FORMA system is able...

Page 18: ...to make it easier to move the unit to the place in which it is to be installed Figure 3 Once the closed fireplace is in position the wheels must be lifted from the floor and removed so that the unit i...

Page 19: ...iance Removal of the feet is deemed to be a structural modification to the product and as such invalidates the guarantee Adjusting the level of the closed fireplace is an essential operation to allow...

Page 20: ...fireplace is installed with forced ventilation in other words using a Comfort Air kit create the air inlets and ducts as follows for correct oxygen exchange in the room we recommend that you include...

Page 21: ...NG TO CLAD THE CLOSED FIREPLACE The closed fireplace and parts of the cladding must be fixed to each other WITHOUT BEING IN CONTACT WITH THE STEEL STRUCTURE This prevents transfer of heat to marble an...

Page 22: ...his warning For correct operation of the room ventilation remember that A convective air inlet of at least 400 cm2 The upper part of the cladding must include an outlet additional to the ducted outlet...

Page 23: ...ontraction during the start up and cooling phases and may therefore squeak slightly This is completely normal given that the structure is made from laminated steel It should therefore not be considere...

Page 24: ...s stable close the door fully 5 3 CHOICE OF FUEL In order to get the best efficiency from your closed fireplace it is of vital importance that you use wood with appropriate characteristics We recommen...

Page 25: ...ted up normal sized wood can be introduced The flame must be as laminar as possible During the various reloading processes the fire door must be opened slowly to avoid smoke being released into the ro...

Page 26: ...ht or left of the closed fireplace using the cold hand supplied This is shown in figure 12 Simply thread the cold hand on the hole and lift the door upwards Reverse this procedure to close the door Du...

Page 27: ...ments This prevents excess combustion The secondary air completes combustion and increases efficiency lever in central position between MAX and MIN When the lever is positioned fully to the right Min...

Page 28: ...BANG AGAINST THE LEDGE AT THE BOTTOM OF THE CLOSED FIREPLACE AND BREAK IT CAUTION Do not spray the cleaner onto the painted parts or onto the seals of the door ceramic fibre cord 6 1 2 Ash removal As...

Page 29: ...erial Never clean the refractory walls with a wet cloth or other items as this may mark the walls At most use a dry brush to remove large masses of soot If the Alutec fails to whiten this is not consi...

Page 30: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901161300 Rev 0 12 2011...

Reviews: