Warnings and guarantee terms 

Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited 

 

 

1. 

WARNINGS AND GUARANTEE 

TERMS 

1.1.  

SAFETY WARNINGS 

 

Installation, electrical connection, 

functional check and maintenance of this 

appliance must only be performed by 

qualified or authorised personnel.

 

 

Install the closed fireplace in compliance 

with the applicable regulations in force in 

the place, region or country. 

 

This appliance must not be used by anyone 

(including children) with limited physical, 

sensory or mental skills or with little 

experience and knowledge, unless they are 

supervised or have been instructed to use 

the device by the person in charge of its 

safety.  

 

Only use the fuel recommended by MCZ. 

The appliance must not be used as an 

incinerator. The use of liquid fuel is strictly 

forbidden. 

 

The instructions provided in this manual must 

always be observed to ensure the correct use of 

this closed fireplace and of any appliances 

connected to it as well as to avoid any accidents. 

 

The user (or anybody preparing to operate the 

closed fireplace) must read and fully understand 

the contents of this instruction manual before 

beginning any operation. 

 

The closed fireplace must only be used for its 

intended purpose. Any other use is considered 

incorrect and therefore dangerous. 

 

Assess the static conditions of the surface on 

which the weight of the closed fireplace will bear 

and provide suitable insulation if it is made of 

flammable material (e.g. wood, fitted carpet, 

plastic). 

 

Avoid installing the appliance in rooms containing 

type B gas appliances or hoods with or without 

an extractor fan, heat pumps, or collective 

ventilation ducts. 

 

Avoid having several operational flue ducts in the 

room or in the proximity of a stair well and make 

sure that there are no appliances in adjacent 

communicating rooms, the concurrent use of 

which causes a vacuum in one of the two rooms. 

 

The user is fully liable for any incorrect use of the 

product. MCZ bears no civil or criminal liability for 

incorrect use. 

 

Tampering of any nature or replacement of spare 

parts with non-original parts may endanger the 

operator. MCZ bears no civil or criminal liability 

for tampering or use of non-original parts.  

 

Parts of the surface of the closed fireplace can 

get very hot (door, handle, glass). Therefore, 

avoid touching these parts without wearing 

suitable protective clothing or using appropriate 

measures, such as heat protective gloves or 

"hands cool" type systems. 

 

Carefully explain this danger to elderly and 

disabled people and, in particular, to all children, 

keeping them away from the closed fireplace 

while it is in use. 

 

Incorrect installation or poor maintenance (not 

conforming to the instructions provided in this 

manual) may cause personal injury, harm to 

animals or damage to property. MCZ bears no 

civil or criminal liability for incorrect installation or 

poor maintenance.

 

1.2.  

OPERATIONAL WARNINGS 

 

Turn off the closed fireplace in the event of a 

failure or malfunctioning. 

 

Keep flammable material at least 150 cm away 

from the glass of the fireplace. 

 

If there is poor draught in the flue pipe (due to 

bad weather, poor installation conditions) light 

the flame strongly, keeping the door slightly 

open. When the door is closed always keep the 

damper completely open. Use dry wood in small 

pieces. If you continue to experience problems 

with the combustion call a qualified technician. 

 

Install the closed fireplace in rooms which are 

suitably protected against fire hazards and 

equipped with all utilities, including power 

supplies (air, water and electricity) and smoke 

outlets. 

 

Do not light the fire with flammable substances.

 

 

INFORMATION

 

In case of any problems please contact your 

retailer or MCZ's qualified, authorised personnel. 

If repairs are necessary, request original spare 

parts. 

 

Check and clean the smoke outlet pipe regularly 

in accordance with the provisions of the 

applicable regulations in the country of 

installation 

 

Keep this instruction manual in a safe place as it 

should accompany the closed fireplace along its 

entire life cycle. If the closed fireplace is sold or 

transferred to another user always ensure that 

the manual accompanies the product. 

 

If this manual is destroyed request a copy from 

your authorised retailer or from MCZ.

 

Summary of Contents for FORMA WOOD 75 DX-SX

Page 1: ...8901161300 USE AND INSTALLATION MANUAL EN...

Page 2: ...ion 13 3 3 Dimensions of the Forma Wood T95 14 3 4 Technical specifications 15 4 INSTALLATION AND ASSEMBLY 16 4 1 PREPARATION AND UNPACKING 16 4 2 OPERATING MODE SELECTION 17 4 2 1 Natural convection...

Page 3: ...nts Technical dept All rights reserved by MCZ Group S p A Reproduction prohibited 6 1 1 Cleaning the glazing 28 6 1 2 Ash removal 28 6 1 3 Cleaning refractory walls ALUTEC 28 6 2 CLEANING UNDER THE RE...

Page 4: ...is document the Manufacturer reserves the right to make any changes without notice All reproduction including partial of this manual without the Manufacturer s authorisation is strictly prohibited Car...

Page 5: ...liability for incorrect use Tampering of any nature or replacement of spare parts with non original parts may endanger the operator MCZ bears no civil or criminal liability for tampering or use of no...

Page 6: ...se manual MCZ cannot be held liable for any damage which may either directly or indirectly be caused to persons animals or property ensuing from failure to observe all the instructions provided in the...

Page 7: ...that present a fire hazard for example garages timber storerooms or warehouses for flammable materials The provisions of all the applicable standards in force must be observed in all circumstances Ins...

Page 8: ...rough hole with a minimum free cross section of 360 cm in the external wall near the closed fireplace 22 cm diameter or 20x18 cm rectangular hole protected by a grille on the inside and on the outside...

Page 9: ...event obstructions nor too short to prevent smoke leakage If metal connections are used it is essential that they be insulated with suitable material such as ceramic fibre to prevent damage to walls a...

Page 10: ...inspect from an airtight flap IMPORTANT If you have doubts about the performance of your flue pipe or if the dimensions of the pipe differ from the recommended values it is highly advisable to have a...

Page 11: ...ain snow and any foreign bodies from penetrating the flue pipe Be positioned so as to ensure adequate dispersion of smoke and in all cases outside the reflux area in which back pressures are likely to...

Page 12: ...roup S p A Reproduction prohibited 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 3 1 Dimensions of the Forma Wood 75 rh lh fig shows lh version 428 258 244 830 750 rivestimento 705 porta 1389 580 rivestim...

Page 13: ...ts reserved by MCZ Group S p A Reproduction prohibited 3 2 Dimensions of the Forma Wood 95 rh lh fig shows lh version 509 72 99 455 porta 467 porta 583 503 rivestimento 1025 900 porta 945 rivestimento...

Page 14: ...s Technical dept All rights reserved by MCZ Group S p A Reproduction prohibited 3 3 Dimensions of the Forma Wood T95 1067 1025 porta 1288 47 137 1026 rivestimento MIN 33 MAX 60 489 rivestimento 514 5...

Page 15: ...smoke 13 O2 0 16 Smoke flow rate 20 1 g s Flue Pipe Up to 5 m 30x30 cm diameter 30 Over 5 m 25x25 cm diameter 25 Notes Intermittent combustion appliance These data may vary according to the type of fu...

Page 16: ...uring transport The carrier or retailer must be informed immediately of any damage If the closed fireplace is installed in a place that is difficult to access the weight can be lightened by removing t...

Page 17: ...esponsibility of the end user in compliance with the applicable laws in force 4 2 OPERATING MODE SELECTION IMPORTANT Decide which system to use before installing the appliance The FORMA system is able...

Page 18: ...to make it easier to move the unit to the place in which it is to be installed Figure 3 Once the closed fireplace is in position the wheels must be lifted from the floor and removed so that the unit i...

Page 19: ...iance Removal of the feet is deemed to be a structural modification to the product and as such invalidates the guarantee Adjusting the level of the closed fireplace is an essential operation to allow...

Page 20: ...fireplace is installed with forced ventilation in other words using a Comfort Air kit create the air inlets and ducts as follows for correct oxygen exchange in the room we recommend that you include...

Page 21: ...NG TO CLAD THE CLOSED FIREPLACE The closed fireplace and parts of the cladding must be fixed to each other WITHOUT BEING IN CONTACT WITH THE STEEL STRUCTURE This prevents transfer of heat to marble an...

Page 22: ...his warning For correct operation of the room ventilation remember that A convective air inlet of at least 400 cm2 The upper part of the cladding must include an outlet additional to the ducted outlet...

Page 23: ...ontraction during the start up and cooling phases and may therefore squeak slightly This is completely normal given that the structure is made from laminated steel It should therefore not be considere...

Page 24: ...s stable close the door fully 5 3 CHOICE OF FUEL In order to get the best efficiency from your closed fireplace it is of vital importance that you use wood with appropriate characteristics We recommen...

Page 25: ...ted up normal sized wood can be introduced The flame must be as laminar as possible During the various reloading processes the fire door must be opened slowly to avoid smoke being released into the ro...

Page 26: ...ht or left of the closed fireplace using the cold hand supplied This is shown in figure 12 Simply thread the cold hand on the hole and lift the door upwards Reverse this procedure to close the door Du...

Page 27: ...ments This prevents excess combustion The secondary air completes combustion and increases efficiency lever in central position between MAX and MIN When the lever is positioned fully to the right Min...

Page 28: ...BANG AGAINST THE LEDGE AT THE BOTTOM OF THE CLOSED FIREPLACE AND BREAK IT CAUTION Do not spray the cleaner onto the painted parts or onto the seals of the door ceramic fibre cord 6 1 2 Ash removal As...

Page 29: ...erial Never clean the refractory walls with a wet cloth or other items as this may mark the walls At most use a dry brush to remove large masses of soot If the Alutec fails to whiten this is not consi...

Page 30: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901161300 Rev 0 12 2011...

Reviews: