34
6-POSITIONING
Attention!!
All measurements pertaining to positioning are provided in chapter 4 in the technical data table.
KEY
dR = distance from flammable material - back
dL = distance from flammable material - side radiation
dS = distance from flammable material - side
dC = minimum distance from ceiling
dB = distance from flammable material - underneath
K =safety distance for radiation
dP = distance from flammable material - front
H = house room height
dF = distance from flammable material - downwards radiation
If the closed fireplace is positioned over a floor or near flammable walls, it is necessary to provide adequate
insulation.
The hot air outlet vents need to be positioned at least 400 mm from other materials (ex. curtains).
If a = NON-FLAMMABLE WALL
CONSIDER THE SAFETY DISTANCE WITHOUT
INSULATING MATERIAL (*)
* If the non-combustible wall is a partition
wall shared by another dwelling and/or
room (considering the possibility of having,
next to the partition, flammable material),
apply the minimum insulation to ensure
safety (30 + 30 mm)
The safety distance (side) k is a safety
distance for irradiation 700 mm
PLEASE NOTE Safety distances are
mandatory
a
= FLAMMABLE WALL
i
= EXAMPLE OF RIGID ROCK WOOL PANEL LINED ON
ONE SIDE WITH AN ALUMINIUM FILM
REACTION TO FIRE EUROCLASS A1
SPECIFIC HEAT Cp=1030 J/(kgK)
DENSITY p=80 kg/m3
min thickness = 30 + 30 mm with staggered joints