Maintenance
2-1
2
Maintenance
Error Indicators
The following error indicators are provided:
Table 2-1
Error LED Indicators
LED
Color
Condition
Description
Power
Green
On
Power on.
Green
Blinking
Power saving mode (sleeping)
Off
Power is off.
Status
Green
On
System ready
Amber
Blinking
System is ready but operating with degraded
performance due to memory or CPU failure. Replace the
unit.
Amber
On
System failure which can be caused by a power module
failure, fan failure, voltage failure, or critical temperature
(overheating). Replace the unit.
Off
System not ready which indicates a post error/NMI
event, or CPU failure. Replace the unit.
HDD
Green
Blinking
Accessing data.
HDD Alert
Amber
On
HDD failure. Replace HDD.
Off
No data access and no HDD failure.
NMI
Amber
On
Non Maskable Interrupt (NMI) PCI bus failure. For this
LED to operate, the NMI setting must be enabled in the
unit BIOS. (This is not the default value). If NMI is
enabled and the LED is on, replace the unit.
Summary of Contents for 1U Server
Page 1: ...1U Server Installation and Service Manual P N 620 000276 000 REV A...
Page 6: ...vi 1U Server Installation and Service Manual Figures...
Page 8: ...viii 1U Server Installation and Service Manual Tables...
Page 16: ...xvi 1U Server Installation and Service Manual Preface...
Page 17: ...Preface xvii Preface...
Page 18: ...xviii 1U Server Installation and Service Manual Preface...
Page 19: ...Preface xix Preface...
Page 20: ...xx 1U Server Installation and Service Manual Preface...
Page 21: ...Preface xxi Preface...
Page 24: ...xxiv 1U Server Installation and Service Manual Preface...
Page 46: ...2 2 10 1U Server Installation and Service Manual Parts Catalog...
Page 48: ...1U Server Installation and Service Manual i 2 Index...