SOLID CONTROL MCK 2000
16
3.3.1 How to adjust the actuators
When installing the
SOLID CONTROL MCK 2000
for the first time, it is important to
calibrate the actuators to enable them to work properly. The factory settings are
made so that the actuator pistons are fully extended when the slits are completely
open (max. distribution of product, Picture 8 - ref. <
A
>) and are fully withdrawn when
the slits are closed. If the specific application requires the opposite set-up (pistons
withdrawn with slits open (Picture 8 - ref. <
B
>), the “Mot” parameter should be
changed as follows:
Switch on the Computer (“ON/OFF” switch) holding down the key
until the
“Mot” parameter is displayed (keep holding for about 20 secs.);
Using the
and
keys, select <0> if the actuators work ion standard set-up,
and <1> if they work in the opposite set-up;
Picture 8
Once the set-up has been established, the actuators can be set (when the
machine is switched off).
N.B.:
if actuators are supplied by
MC elettronica
, the following procedure was
already carried out by the factory.
A
Mot = 0
B
Mot = 1