Do not put the cooker in direct vicinity of wooden elements, cooling devices, plastic 
parts of the furniture and other combustible materials, since it creates high working 
temperature which is distributed at the exterior of the cooker (at the combustion of 
fuel). The least distance between cooker and surrounding elements is 50 cm, and 
combustible materials 80 cm.
If surface on which cooker is to be positioned is made of easily combustible material 
(wood, warm floor, laminated floor...) it is necessary to install metal sheet protection -
lateral width 10 cm, in front 50 cm.
Due to its weight, it is necessary to install cooker on the floor with appropriate 
carrying capacity. If latter does not fulfill requirements, please take proper measures 
to achieve it (e.g. distribution of weight).
Cooker is to be connected with chimney through flue pipes and via connection on the
back side of cooker, in order to provide adequate sealing and smoke flow from 
cooker to the chimney. Flue pipe may not be installed too deeply into the chimney to 
avoid reduction of cross-section of the surface thus impairing draft in chimney. Do 
not use reducers which would reduce cross-section of the smoke exhaust pipe (flue 
pipe).
Cooker requires intake of fresh air into the room in which it is installed, whereat 
surface of the opening for intake of fresh air may not be smaller then 0,4 dm². Device
for intake of fresh air is to be mounted outside collective room for ventilation which 
must be secured with doors and grid.
Ventilators which work in the same room in which cooker is mounted may create 
disturbances with the cooker operation. Also, all devices or air conditioning which 
make sub-pressure in the room in which cooker is installed must be adjusted not to 
make decompression which disables normal operation of the cooker.

Prior to installation of the cooker, check draft in the chimney since it is one of the key
factors of proper operation.  Draft depends on accuracy of the chimney and 
meteorological conditions. One of the simplest aspects for checking of the draft in 
the chimney is using candle flame, as illustrated in the figure 2. Candle flame is to be
offered to connection opening of the chimney and, if it sways towards opening, draft 
is satisfactory (fig. 2b). Weak swaying of the flame is indicator of weak draft (fig. 2a).

Fig. 2a.                                                              Fig. 2b.

Summary of Contents for Super Thermo Magnum

Page 1: ...MANUAL INSTRUCTION Solid fuel cooker for central heating SUPER THERMO MAGNUM...

Page 2: ...nical characteristics which place it into top class and you will be assured of it during exploitation Please carefully read this manual before you start to use this cooker since you will find tips and...

Page 3: ...1 Description 2 Installation 4 Installing cooker into the system of water heating 6 Managing operation of the cooker 10 Firing and ignition 11 Cleaning and maintenance 12 General notes 13 Advices for...

Page 4: ...ndling Do no allow children to handle and play in vicinity of the cooker Only spare parts approved by the manufacturer may be installed on the cooker Do not make any changes to the cooker At the first...

Page 5: ...fig 1 pos 1 with gray cast iron smoke exhaust fig 1 pos 7 which is mounted onto the plate with two screws Firebox door fig 1 pos 8 are made of gray cast iron and has thermalproof transparent glass fig...

Page 6: ...characteristics 1 Nominal thermal power kW 21 2 Efficiency 87 3 Thermal power given to water kW 13 4 Thermal power given to room kW 8 5 Dimensions WxDxH mm 1060x650x860 6 Dimensions of firebox WxDxH...

Page 7: ...of the surface thus impairing draft in chimney Do not use reducers which would reduce cross section of the smoke exhaust pipe flue pipe Cooker requires intake of fresh air into the room in which it is...

Page 8: ...imney may be fig 3 1 Chimney is lower then top of the roof small cross section of the exit 2 Too large slope 3 Abrupt alteration of the direction of smoke channel 4 Cooker or other device connected to...

Page 9: ...max 3 bar boiler is tested for 4 bar Connection guide of safety valve must be as shorter as possible and may not be capable for closing This guide also may not contain any valve or any other fixing Cl...

Page 10: ...lusively carried out by expert who guarantees proper work of entire heating system In case of weakly designed system and eventual omissions upon works by mentioned person complete material responsibil...

Page 11: ...f unpleasant scents Firing up in the firebox should be carried out as follows open firebox and ashtray door and pull primary air handle put into the firebox some firing materials chopped wood on non g...

Page 12: ...ng of cooker and possible explosion Attention Do not use organic residues food residues plastic objects combustible and explosive materials as fuel since their combustion disturbs proper operation of...

Page 13: ...ng walls and characteristic smell of flare If fire occurs take following steps Immediately call fire department Suppress oxygen inflow into the chimney and turn off the cooker Do not put anything in c...