IRREGULARITIES IN OPERATION AND TROUBLESHOOTING

In the following table, there are most frequent operating irregularities and 
troubleshooting.
Table: Display of the most frequent irregularities, possible causes and 
troubleshooting.

Problem

Possible cause

Remedy

Cooker weakly heats 
and cooks

Irregular handling

Bad chimney

Carefully read and 
observe manual

In case if all conditions 
from the manual are 
fulfilled and problem still 
persists, call service

Problems with firing 
up

closed air intake 
regulator 

wet woods

lack of oxygen

open air intake regulator 

and provide primary air intake

use dry woods

ventilate the room to 
provide fresh air

Smoke is coming 
below the plate

closed air intake 
regulator 

lack of draft

unclean ash from 
the grid

open air intake regulator 
and provide  primary air 
intake

carefully read manual and 
apply tips for providing air 
flow

clean the grid

Firebox door glass 
has tar after a short 
period of operation

wet woods

too much fuel 

lack of draft

closed secondary 
air intake

use dry woods

see recommended amount
of fuel for combustion 
given in the manual

check connection with the 
chimney

carefully read manual and 
apply tips for providing 
secondary air

GENERAL NOTES

If all installation recommendations, operating and cleaning regulation given in this 
manual are met, cooker represents proven and safe household device.
Prior to installation, remove the package. Take care of possible injuries since 
wooden battens on packaging have nails. Dispose of plastic bag in the proper place 
according to the local regulations. Old cooker which will not be used in the future 
should be disposed of according to the local regulations.
All claims, evaluated as defects or weak functioning of the cooker should be reported
to manufacturer or authorized service via phone or in written form with fiscal bill 
attached. All contact information is given at the end of this manual.
All defects on the cooker are to be repaired exclusively by the manufacturer.
If unauthorized personnel make any servicing or repairs or changes, owner of the 
cooker will lose the right to service guaranteed by the manufacturer.
Purchase of spare parts is to be done exclusively through manufacturer, based on 
positions and figures or their names in this manual.
Manufacturer shall not bear any liability if purchaser does not observe instructions 
and installation manual.

Summary of Contents for Super Thermo Magnum

Page 1: ...MANUAL INSTRUCTION Solid fuel cooker for central heating SUPER THERMO MAGNUM...

Page 2: ...nical characteristics which place it into top class and you will be assured of it during exploitation Please carefully read this manual before you start to use this cooker since you will find tips and...

Page 3: ...1 Description 2 Installation 4 Installing cooker into the system of water heating 6 Managing operation of the cooker 10 Firing and ignition 11 Cleaning and maintenance 12 General notes 13 Advices for...

Page 4: ...ndling Do no allow children to handle and play in vicinity of the cooker Only spare parts approved by the manufacturer may be installed on the cooker Do not make any changes to the cooker At the first...

Page 5: ...fig 1 pos 1 with gray cast iron smoke exhaust fig 1 pos 7 which is mounted onto the plate with two screws Firebox door fig 1 pos 8 are made of gray cast iron and has thermalproof transparent glass fig...

Page 6: ...characteristics 1 Nominal thermal power kW 21 2 Efficiency 87 3 Thermal power given to water kW 13 4 Thermal power given to room kW 8 5 Dimensions WxDxH mm 1060x650x860 6 Dimensions of firebox WxDxH...

Page 7: ...of the surface thus impairing draft in chimney Do not use reducers which would reduce cross section of the smoke exhaust pipe flue pipe Cooker requires intake of fresh air into the room in which it is...

Page 8: ...imney may be fig 3 1 Chimney is lower then top of the roof small cross section of the exit 2 Too large slope 3 Abrupt alteration of the direction of smoke channel 4 Cooker or other device connected to...

Page 9: ...max 3 bar boiler is tested for 4 bar Connection guide of safety valve must be as shorter as possible and may not be capable for closing This guide also may not contain any valve or any other fixing Cl...

Page 10: ...lusively carried out by expert who guarantees proper work of entire heating system In case of weakly designed system and eventual omissions upon works by mentioned person complete material responsibil...

Page 11: ...f unpleasant scents Firing up in the firebox should be carried out as follows open firebox and ashtray door and pull primary air handle put into the firebox some firing materials chopped wood on non g...

Page 12: ...ng of cooker and possible explosion Attention Do not use organic residues food residues plastic objects combustible and explosive materials as fuel since their combustion disturbs proper operation of...

Page 13: ...ng walls and characteristic smell of flare If fire occurs take following steps Immediately call fire department Suppress oxygen inflow into the chimney and turn off the cooker Do not put anything in c...

Page 14: ...ning of external surfaces with soft cloth which will not damage the cooker surfaces Chemical cleaning agents may be used and don t damage surfaces of the oven Do not clean colored and enameled surface...

Page 15: ...ual check connection with the chimney carefully read manual and apply tips for providing secondary air GENERAL NOTES If all installation recommendations operating and cleaning regulation given in this...

Page 16: ...sposing of wooden battens since they are nailed Product Device is made of materials which may be recycled At the disposal of waste Observe local environmental laws Use only recommended fuels It is for...