against eventual overheating. We recommend safety thermal valve
Caleffi 544 1/2
shown on fig. 2.
Comment:
Safety thermal valve is not part of the product and will not be delivered
with cooker. Guarantee for the boiler is valid exclusively with built-in thermal valve.
Fig. 2: Safety thermal valve Caleffi
TECHNICAL CHARACTERISTICS
Table 1. Technical characteristics
No
Technical characteristics
1.
Nominal thermal power (kW)
21
2.
Efficiency (%)
87
3.
Thermal power given to water (kW)
13
4.
Thermal power given to room (kW)
8
5.
Dimensions WxDxH (mm)
1060x650x860
6.
Dimensions of firebox WxDxH (mm)
400x430x310
7.
Amount of water in boiler (l)
19
8.
Fume outlet diameter (mm)
130
9.
Connections for water pipe (")
1
10.
Draft (Pa)
15
11.
Temperature of smoke gasses (°C)
240
12.
Maximal water temperature (°C)
80
13.
Recommended fuel
beech wood
14.
Consumption of fuel at nominal power (kg/h)
5.2
15.
Maximal working pressure (bar)
3
16.
Dust emission (mg/m³)
39
17.
Contents of CO
0.07
INSTALLATION