background image

 
One of the aspects of installation is shown on fig. 6.
At this system, starting guide is to be installed with safety distribution guide of 
expansion vessel and valve of boiler, and on starting guide valve of boiler is to be 
installed, as well as pump and valve. Directly below open expansion vessel there 
must be short connection of safety distribution guide and safety return guide, which 
in winter prevents freezing of water in expansion vessel.
On safety distribution and safety returning guide there may not be any fixture. 
Expansion vessel itself must have overflow duct as shown on diagram 7. Volume of 
expansion vessel is to be determined by the pattern: 

V = 0,07x V water, (l), where V water is water volume and entire power plant.

Open expansion vessel is to be installed vertically above the highest heating body. 
At open heating system, gravitaion system of heating is possible.

Note:

 Mounting of heating and putting into operation of entire system should be 

exclusively carried out by expert who guarantees proper work of entire heating 
system. In case of weakly designed system and eventual omissions upon works by 
mentioned person, complete material responsibility shall be borne exclusively by 
person who carreid out installation of heating system,not manufacturer, 
representative or retailer of the boiler.

Important

• Installation of cooker should be carried out by expert according to appropriate 
project design. Cooker construction enables connection to open or closed heating 
system. All connections must be well sealed and tightened. Prior to operation, 
complete installation should be inspected with water under pressure of 3 bar.

• upon installation of safety valve, pay attention to direct connection with aqueduct 
and sewage, and if valves (taps) are always open.

• If reinforced hose is used for connection with drainage opening, it must be removed
from back side of cooker.

At the first firing up,

 it is necessary to inspect accuracy of valve by short-term 

overheating up to 100°C, and then inspect accuracy of air flow regulator and 
installation for distribution of hot water to radiators, as well as radiators themselves.

Summary of Contents for Super Thermo Magnum

Page 1: ...MANUAL INSTRUCTION Solid fuel cooker for central heating SUPER THERMO MAGNUM...

Page 2: ...nical characteristics which place it into top class and you will be assured of it during exploitation Please carefully read this manual before you start to use this cooker since you will find tips and...

Page 3: ...1 Description 2 Installation 4 Installing cooker into the system of water heating 6 Managing operation of the cooker 10 Firing and ignition 11 Cleaning and maintenance 12 General notes 13 Advices for...

Page 4: ...ndling Do no allow children to handle and play in vicinity of the cooker Only spare parts approved by the manufacturer may be installed on the cooker Do not make any changes to the cooker At the first...

Page 5: ...fig 1 pos 1 with gray cast iron smoke exhaust fig 1 pos 7 which is mounted onto the plate with two screws Firebox door fig 1 pos 8 are made of gray cast iron and has thermalproof transparent glass fig...

Page 6: ...characteristics 1 Nominal thermal power kW 21 2 Efficiency 87 3 Thermal power given to water kW 13 4 Thermal power given to room kW 8 5 Dimensions WxDxH mm 1060x650x860 6 Dimensions of firebox WxDxH...

Page 7: ...of the surface thus impairing draft in chimney Do not use reducers which would reduce cross section of the smoke exhaust pipe flue pipe Cooker requires intake of fresh air into the room in which it is...

Page 8: ...imney may be fig 3 1 Chimney is lower then top of the roof small cross section of the exit 2 Too large slope 3 Abrupt alteration of the direction of smoke channel 4 Cooker or other device connected to...

Page 9: ...max 3 bar boiler is tested for 4 bar Connection guide of safety valve must be as shorter as possible and may not be capable for closing This guide also may not contain any valve or any other fixing Cl...

Page 10: ...lusively carried out by expert who guarantees proper work of entire heating system In case of weakly designed system and eventual omissions upon works by mentioned person complete material responsibil...

Page 11: ...f unpleasant scents Firing up in the firebox should be carried out as follows open firebox and ashtray door and pull primary air handle put into the firebox some firing materials chopped wood on non g...

Page 12: ...ng of cooker and possible explosion Attention Do not use organic residues food residues plastic objects combustible and explosive materials as fuel since their combustion disturbs proper operation of...

Page 13: ...ng walls and characteristic smell of flare If fire occurs take following steps Immediately call fire department Suppress oxygen inflow into the chimney and turn off the cooker Do not put anything in c...

Page 14: ...ning of external surfaces with soft cloth which will not damage the cooker surfaces Chemical cleaning agents may be used and don t damage surfaces of the oven Do not clean colored and enameled surface...

Page 15: ...ual check connection with the chimney carefully read manual and apply tips for providing secondary air GENERAL NOTES If all installation recommendations operating and cleaning regulation given in this...

Page 16: ...sposing of wooden battens since they are nailed Product Device is made of materials which may be recycled At the disposal of waste Observe local environmental laws Use only recommended fuels It is for...

Reviews: