- 7 -
GB
2.6
ELECTRICAL CONNECTION
The electrical connection must be carried out by qualified authorized personnel only, in compliance with the regulations in
force. Check the data reported in the technical data Table on page 4 of this manual, on the adhesive connection label on page
11 and in the wiring diagram. The connection envisaged is fixed.
IMPORTANT
: A multi-polar mains cut-off device must be provided upstream from each oven, with a contact opening gap of
at least 3 mm.
For example:
- a manual switch of suitable capacity, equipped with fuses
- residual current device.
2.6.1
EARTHING
It is vital to earth the oven.
Connect the terminals marked by
the symbols ( ) positioned on the line-in terminal block
to an efficient grounding complying with the regulations in
force.
CAUTION: NEVER CUT THE GROUNDING CABLE
(yellow-green)
THE MANUFACTURER DISCLAIMS ALL
RESPONSIBILITY IF THESE SAFETY STANDARDS ARE
NOT COMPLIED WITH.
2.6.2
EQUIPOTENTIAL SYSTEM
The oven must be included in an equipotential system whose
efficiency must be checked according to the standards in force.
The screw marked by the ”Equipotential” (Fig. 3 Pos. A) label
is near the terminal block on the base.
2.6.4
POWER SUPPLY CABLE
The oven is supplied without a power cable. The specifications
of the power supply connection flexible cable must match or
be superior to those of the cable with rubber insulation H07RN-
F.
As regards the cross-sections of cables, refer to the table on
page 12. Introduce the cable through the cable clamp (Fig.4
Pos. B) and secure it firmly. During operation, the power supply
voltage should not differ from the voltage rating by +/-10%.
Fig.3
A
Fig.4
C
B
A