- 8 -
GB
3N AC 380...415 V 50 Hz
3 AC 220...240 V 50 Hz
AC 220...240 V 50 Hz
PE (Earth) yellow - green
N
(NP)
blue
L
3
(T)
black
L
2
(S)
black
L
1
(R)
bronwn
PE (Earth) yellow - green
L
3
(T)
blue
L
2
(S)
black
L
1
(R)
bronwn
PE (Earth) yellow - green
N
(NP)
blue
L
1
(R)
bronwn
MODEL
TYPE OF VOLTAGE
FCE 6
FCE 10
FCE 20
I max.
A/f
No. cables
mm
2
3N AC 380...415 V 50 Hz
3 AC 220...240 V 50 Hz
AC 220...240 V 50 Hz
WIRING DIAGRAM
DRAWING No.
10,9
18,8
32,7
5 x 1,5
4 x 2,5
3 x 6
11377
I max.
A/f
No. cables
mm
2
24,3
39,9
67,8
5 x 2,5
4 x 6,0
-
11384
I max.
A/f
No. cables
mm
2
33
57
-
5 x 6,0
4 x 10,0
-
12426
2.6.6
CONNECTIONS TO THE DIFFERENT ELECTRICAL NETWORKS
2.6.5
ELECTRIC CONNECTION OF THE CABLE TO THE TERMINAL BOARD
Equipment is manufactured to operate with the following voltage values:
3N AC 380...415 V; 3 AC 220....240 V or AC 220....240 V 50 Hz.
(in case of 60 Hz. power supply, request the appropriate kit).
If it is to be connected to one of these voltages, proceed as follows:
• Remove the right panel.
• Connect the power supply cable to the terminal block according to the mains voltage, following the wiring diagram and the
adhesive connection label placed near the terminal block.
• Fasten the cable-clamp firmly after inserting a sufficient length of cable.