Service / Parts Information ______

Service

Service must be performed by a qualified trained technician, 

service agency, or gas supplier. If service is required, contact the 

Maytag distributor from whom the equipment was purchased. If 

the distributor cannot be contacted or is unknown, contact the 

Whirlpool Commercial Laundry for a distributor in your area.

NOTE:

 When contacting the Whirlpool Commercial Laundry, be 

sure to give them the correct model number and serial number 

so that your inquiry is handled in an expeditious manner.

Parts

Replacement parts should be purchased from the distributor 

from whom the Maytag equipment was purchased. If the 

distributor cannot be contacted or is unknown, contact the 

Maytag Co. for a distributor in your area.

NOTE:

 When ordering replacement parts from the Maytag 

distributor or the Maytag Co. be sure to give them the correct 

model number and serial number so that your parts order can 

be processed in an expeditious manner.

Routine Maintenance ___________

A program should be established for the inspection and cleaning 

of lint in the burner area, exhaust ductwork, and area around the 

back of the dryer. The frequency of inspection and cleaning can 

best be determined from experience at each location.
Exhaust duct outlet should be checked periodically for 

blockages, and if any found, removed.

Cleaning

A program and/or schedule should be established for periodic 

inspection, cleaning, and removal of lint from various areas 

of the dryer, as well as throughout the ductwork system. The 

frequency of cleaning can best be determined from experience 

at each location. Maximum operating efficiency is dependent 

upon proper airflow. The accumulation of lint can restrict this 

airflow.

NOTE:

 Suggested time intervals shown are for average usage, 

which is considered 6 to 8 operational (running) hours per day.

IMPORTANT:

 Be sure to reinstall all parts removed during 

cleaning.
Every 6 months, inspect the exhaust ducting and remove any 

lint buildup.

Suggested Cleaning Schedule

Every Third or Fourth Load

Clean the lint screen every third or fourth load. A clogged lint 

screen will cause poor dryer performance. The lint door/ drawer 

is located just below the loading door of the dryer. Open the lint 

door/drawer, brush the lint off the lint screen, and remove the 

lint. Inspect lint screen and replace if torn.

NOTE:

 To remove the lint drawer from the dryer first pull the 

screen out roughly half way and lift the clip on the lower left side 

of the lint drawer up. Now you will be able to pull the lint drawer 

completely out.

IMPORTANT:

 The frequency of cleaning the lint screen can best 

be determined from experience at each location.

Weekly

Clean lint accumulation from lint chamber, thermostat, and 

microprocessor temperature sensor area.

90 Days

Remove lint from gas valve burner area with a dusting brush or 

vacuum cleaner attachment.
Clean any lint accumulation in and around the motor(s) casing 

opening.

NOTE:

 To prevent damage, avoid cleaning and/or touching 

ignitor/flame-probe assembly.

Every 6 Months

Inspect and remove lint accumulation in customer furnished 

exhaust ductwork system and from dryer’s internal exhaust 

ducting.

NOTE:

 Do not obstruct the flow of combustion and ventilation 

air. Check back draft dampers in the exhaust ductwork. Inspect 

and remove any lint accumulation, which can cause the damper 

to bind or stick.
A back draft damper that is sticking partially closed can result 

in slow drying and shutdown of heat circuit safety switches or 

thermostats.
When cleaning the dryer cabinet(s), avoid using harsh 

abrasives. A product intended for the cleaning of appliances is 

recommended.

Adjustments 
7 Days After Installation and Every 6 Months 

Thereafter

Inspect thermostats, motors, bolts, nuts, screws, setscrews, 

grounding connections and nonpermanent gas connections 

(unions, shutoff valves and orifices). Belts should be examined. 

Cracked or seriously frayed belts should be replaced. Complete 

an operational check of controls and valves. Complete an 

operational check of all safety devices (lint door/drawer switch, 

door switches and sail switch switch).door switches and sail 

switch switch).

Summary of Contents for MLG30

Page 1: ...MLG30 Installation Manual Stack Dryer WFR113543E RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...N HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or...

Page 3: ..._ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column UL Underwriters Laboratory NPT National Pipe Thread Table Of Contents ______________ Caution Label all wires prior to disco...

Page 4: ...kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 400 cfm 11 3 cmm HEAT INPUT PER POCKET 72000 Btu hr 18143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm INLET PIPE CONNECTION PER POCKE...

Page 5: ...nform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affe...

Page 6: ...r 1 000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up...

Page 7: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork may need to be increased IMPORTANT For extended ductwork runs the cross section area of the ductwork can onl...

Page 8: ...RICAL SERVICE SPECIFICATIONS PER POCKET NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying eithe...

Page 9: ...onnection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label Fire Hazard Use appropriate gauge of copper wire See chart in Electrica...

Page 10: ...country of destination and if in doubt the installer must contact the supplier The manufacturer of this dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that res...

Page 11: ...immediately upstream of the dryer Test all connections for leaks by brushing on a soapy water solution liquid detergent works well 3 4 x 1 2 x 1 2 TEE 19 05 mm x 12 7 mm x 12 7 mm SEE IMPORTANT NOTE...

Page 12: ...ry adjustments have been made the dryer must be operated in a heating cycle to verify that the pressure is correct 6 Feed manometer hose through an opening in the back panel while reattaching the back...

Page 13: ...uctions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put int...

Page 14: ...y lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is l...

Page 15: ...Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure ta...

Page 16: ...MLG30 Manuel d installation S cheuse superpos e CONSERVER CES INSTRUCTIONS POUR R F RENCE ULT RIEURE...

Page 17: ...ce ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas tou...

Page 18: ...on et Climatisation po CE Pouces de colonne d eau UL Underwriters Laboratory NPT National Pipe Thread Attention Lors des contr les d entretien placer des tiquettes sur l ensemble des c bles avant leur...

Page 19: ...UEMENT APPROXIMATIF 710 lb 322 kg D BIT D AIR PAR S CHEUSE 400 pi min 11 3 m3 min ENTR E DE CHALEUR PAR S CHEUSE 72 000 Btu h 18 143 kcal h RACCORD D VACUATION DIAM TRE 8 po 20 3 cm RACCORD D ENTR E D...

Page 20: ...z naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNI RE DITION pour l installation g n rale et la plomberie au gaz L utilisation de cette s cheuse peut affecter celle d autres s cheuses gaz dont la...

Page 21: ...uverture d air d appoint distincte pour chaque s cheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent tre install es de sorte que l air d appoint est distribu u...

Page 22: ...onduit IMPORTANT Pour les conduits de longueur prolong e l aire de la section transversale du conduit ne peut tre augment e que dans une certaine mesure Lorsque le nombre de conduits approche les limi...

Page 23: ...fusibles sont utilis s ils doivent comporter deux l ments tre temporis s de type limiteur de courant classe RK1 ou RK5 UNIQUEMENT Calculez d terminez la bonne valeur de fusible conforme aux codes lec...

Page 24: ...du circuit de 120 V 15 A au conducteurs restants s cheuse inf rieure comme d crit dans l illustration suivante noir noir blanc blanc et vert au fil de terre du ch ssis Serrer les vis du r ducteur de t...

Page 25: ...heuse l usine Le r glage ou la conversion des s cheuses sur le terrain pour des altitudes sup rieures 2 000 pi 610 m est effectu en changeant chaque orifice du br leur Si cette conversion est n cessai...

Page 26: ...les raccordements pour la pr sence des fuites en appliquant une solution d eau savonneuse le d tergent liquide fonctionne bien RACCORD EN T DE 3 4 po x 1 2 po x 1 2 po 19 05 mm x 12 7 mm x 12 7 mm VO...

Page 27: ...ns le sens antihoraire pour abaisser la pression REMARQUE La pression de sortie est mesur e pendant que le br leur est en marche pour toutes les conditions de r glage du br leur Par cons quent une foi...

Page 28: ...fi s en cours de route ou en raison de conditions d emplacement marginales installation Mettre sous tension la s cheuse Voir les instructions d installation pour mettre la s cheuse en marche Ouvrir to...

Page 29: ..._________________ R paration La r paration doit tre effectu e par un technicien ou une entreprise de r paration ayant les qualifications requises ou par le fournisseur de gaz Si une r paration est n c...

Page 30: ...VEC DES ELEVATIONS ENTRE 610 A 1372M Assembled in Assemble aux USA Whirlpool Corporation TEL 269 923 3000 88 Currant Road FAX 508 678 9447 Fall River MA 02720 4781 mdl service whirlpool com WWW WHIRLP...

Page 31: ...31...

Page 32: ...WFR113543E 03 20 TM 2020 Maytag All rights reserved Tous droits r serv s...

Reviews: