Electrical Information ___________

Electrical Requirements

All electrical connections must be made by a properly licensed 

electrician. This is to ensure that the electrical installation is 

adequate and conforms to local, state, and national regulations 

or codes of the country of destination. In the absence of such 

codes, all electrical connections, materials, and workmanship 

must conform to the applicable requirements of the National 

Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in 

Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-

1990 or LATEST EDITION.

IMPORTANT:

 Failure to comply with these codes or ordinances, 

and/or the requirements stipulated in this manual can result in 

personal injury or component failure.

NOTE:

 Component failure due to improper installation will void 

the warranty.
Each pocket should be connected to an independently protected 

branch circuit. The dryer must be connected with copper wire 

only. Do not use aluminum wire. The copper conductor wire/

cable must be of proper ampacity and insulation in accordance 

with electric codes for making all service connections.

NOTE:

 The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to each pocket, do 

not daisy chain.
Component failure due to improper voltage application will void 

the warranty.
The manufacturer reserves the right to make changes in 

specifications at any time without notice or obligation.

IMPORTANT:

 A separate protected circuit must be provided to 

each pocket.
It is necessary to have a power disconnect for each pocket. 

These disconnects must be located within 30' (9 m) of the 

dryer and also be identified as being one of two power sources 

supplying a dryer.
The dryer must be connected to the electric supply shown on 

the data label.

Electrical Service Specifications

ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)

NOTES:

A.  When fuses are used they must be dual 

element, time delay, current limiting, class RK1 

or RK5 ONLY. Calculate/determine correct fuse 

value, by applying either local and/or National 

Electrical Codes to listed appliance amp draw 

data

.

B.  Circuit breakers are thermal-magnetic 

(industrial) motor curve type ONLY. For others, 

calculate/verify correct breaker size according 

to appliance amp draw rating and type of 

breaker used.

SERVICE 

VOLTAGE

PHASE

WIRE 

SERVICE

APPROX. 

AMP 

DRAW

CIRCUIT 

BREAKER

MINIMUM 

WIRE GAUGE

60 Hz

120

2

8.7

15

14

Grounding

A ground (earth) connection must be provided and installed in 

accordance with local, state, and national regulations or codes 

of the country of destination. In the absence of these codes, 

grounding must conform to applicable requirements of the 

National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, 

or in Canada, the installation must conform to applicable Canada 

Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-

1990 or LATEST EDITION. The ground connection may be to a 

proven earth ground at the location service panel.

D

W

H

2 x D CLEARANCE

NOTE A

NOTE A

HORIZONTAL

VERTICAL

TO INDIVIDUAL 

DRYERS

INSPECTION DOORS

TUMBLER EXHAUST MUST ENTER MAIN 

EXHAUST DUCT AT 45o ANGLE

29.625

"

(75.25 cm) MINIMUM 

DISTANCE BETWEEN 

DUCTS

IMPORTANT: NO MORE THAN 4 DRYERS (8 TUMBLERS) 

CAN BE CONNECTED TO ONE COMMON DUCT (VENT).

NOTE A: OPENING MUST BE 2

"

(5.08 cm) LARGER THAN THE DUCT (ALL THE 

WAY AROUND). THE DUCT MUST BE CENTERED WITHIN THIS OPENING.

FORMULAS TO CALCULATE DUCTING CROSS SECTIONAL AREA 

CROSS SECTIONAL AREA OF A ROUND DUCT= 0.785(19.939 mm) 

x D2 WHERE D= DIAMETER OF THE DUCT 

CROSS SECTIONAL AREA OF A RECTANGULAR DUCT= W x H 

WHERE W= WIDTH AND H= HEIGHT

MULTIPLE DRYER VENTING WITH 10

"(25.4 cm) DIAMETER EXHAUST 

CONNECTIONS AT COMMON DUCT

NO OF DRYERS

4

3

2

1

MINIMUM CROSS (SQ IN) 

SECTION AREA (SQ CM)

210

164

120

80

1354

1058

774

516

MINIMUM ROUND (IN) 

DUCT DIAMETER (CM)

16

14

12

10

40

35

30

25

2 x D CLEARANCE

30' MAXIMUM 

9.1 m

D WALL

ROOF

Summary of Contents for MLG30

Page 1: ...MLG30 Installation Manual Stack Dryer WFR113543E RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...N HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or...

Page 3: ..._ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column UL Underwriters Laboratory NPT National Pipe Thread Table Of Contents ______________ Caution Label all wires prior to disco...

Page 4: ...kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 400 cfm 11 3 cmm HEAT INPUT PER POCKET 72000 Btu hr 18143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm INLET PIPE CONNECTION PER POCKE...

Page 5: ...nform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affe...

Page 6: ...r 1 000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up...

Page 7: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork may need to be increased IMPORTANT For extended ductwork runs the cross section area of the ductwork can onl...

Page 8: ...RICAL SERVICE SPECIFICATIONS PER POCKET NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying eithe...

Page 9: ...onnection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label Fire Hazard Use appropriate gauge of copper wire See chart in Electrica...

Page 10: ...country of destination and if in doubt the installer must contact the supplier The manufacturer of this dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that res...

Page 11: ...immediately upstream of the dryer Test all connections for leaks by brushing on a soapy water solution liquid detergent works well 3 4 x 1 2 x 1 2 TEE 19 05 mm x 12 7 mm x 12 7 mm SEE IMPORTANT NOTE...

Page 12: ...ry adjustments have been made the dryer must be operated in a heating cycle to verify that the pressure is correct 6 Feed manometer hose through an opening in the back panel while reattaching the back...

Page 13: ...uctions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put int...

Page 14: ...y lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is l...

Page 15: ...Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure ta...

Page 16: ...MLG30 Manuel d installation S cheuse superpos e CONSERVER CES INSTRUCTIONS POUR R F RENCE ULT RIEURE...

Page 17: ...ce ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas tou...

Page 18: ...on et Climatisation po CE Pouces de colonne d eau UL Underwriters Laboratory NPT National Pipe Thread Attention Lors des contr les d entretien placer des tiquettes sur l ensemble des c bles avant leur...

Page 19: ...UEMENT APPROXIMATIF 710 lb 322 kg D BIT D AIR PAR S CHEUSE 400 pi min 11 3 m3 min ENTR E DE CHALEUR PAR S CHEUSE 72 000 Btu h 18 143 kcal h RACCORD D VACUATION DIAM TRE 8 po 20 3 cm RACCORD D ENTR E D...

Page 20: ...z naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNI RE DITION pour l installation g n rale et la plomberie au gaz L utilisation de cette s cheuse peut affecter celle d autres s cheuses gaz dont la...

Page 21: ...uverture d air d appoint distincte pour chaque s cheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent tre install es de sorte que l air d appoint est distribu u...

Page 22: ...onduit IMPORTANT Pour les conduits de longueur prolong e l aire de la section transversale du conduit ne peut tre augment e que dans une certaine mesure Lorsque le nombre de conduits approche les limi...

Page 23: ...fusibles sont utilis s ils doivent comporter deux l ments tre temporis s de type limiteur de courant classe RK1 ou RK5 UNIQUEMENT Calculez d terminez la bonne valeur de fusible conforme aux codes lec...

Page 24: ...du circuit de 120 V 15 A au conducteurs restants s cheuse inf rieure comme d crit dans l illustration suivante noir noir blanc blanc et vert au fil de terre du ch ssis Serrer les vis du r ducteur de t...

Page 25: ...heuse l usine Le r glage ou la conversion des s cheuses sur le terrain pour des altitudes sup rieures 2 000 pi 610 m est effectu en changeant chaque orifice du br leur Si cette conversion est n cessai...

Page 26: ...les raccordements pour la pr sence des fuites en appliquant une solution d eau savonneuse le d tergent liquide fonctionne bien RACCORD EN T DE 3 4 po x 1 2 po x 1 2 po 19 05 mm x 12 7 mm x 12 7 mm VO...

Page 27: ...ns le sens antihoraire pour abaisser la pression REMARQUE La pression de sortie est mesur e pendant que le br leur est en marche pour toutes les conditions de r glage du br leur Par cons quent une foi...

Page 28: ...fi s en cours de route ou en raison de conditions d emplacement marginales installation Mettre sous tension la s cheuse Voir les instructions d installation pour mettre la s cheuse en marche Ouvrir to...

Page 29: ..._________________ R paration La r paration doit tre effectu e par un technicien ou une entreprise de r paration ayant les qualifications requises ou par le fournisseur de gaz Si une r paration est n c...

Page 30: ...VEC DES ELEVATIONS ENTRE 610 A 1372M Assembled in Assemble aux USA Whirlpool Corporation TEL 269 923 3000 88 Currant Road FAX 508 678 9447 Fall River MA 02720 4781 mdl service whirlpool com WWW WHIRLP...

Page 31: ...31...

Page 32: ...WFR113543E 03 20 TM 2020 Maytag All rights reserved Tous droits r serv s...

Reviews: