The illustration below shows the minimum cross-sectional
area for multiple dryer round or square venting.  These figures
must be increased if the main duct run from the last dryer to
where it exhausts to the outdoors is longer than 20 feet (6.09
meters) or has more than 1 elbow in it.

Multiple Dryer Venting with 10-Inch (25.4 cm) Diameter

1,200 cfm (33.98 cmm) Exhaust Connections at Common Duct

NOTE 1

Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around).  The duct must be centered
within this opening.

NOTE 2

Distance should be 2 times the diameter of the duct to the nearest
obstruction.

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

600 cfm (16.99 cmm) Exhaust Connections at Common Duct

A = 10-inches (25.4 cm)   B = 20 feet (6.09 meters)

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

254

200

155

80

SQ CM

1638

1290

999

516

MINIMUM ROUND
DUCT DIAMETER

IN

18

16

14

10

CM

45.72

40.64

35.56

25.4

A = 8-inches (20.32 cm)
B = 20 feet (6.09 meters)

NUMBER  OF  DRYERS

8

7

6

5

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

254

200

155

80

SQ CM

1638

1290

999

516

MINIMUM ROUND
DUCT DIAMETER

IN

18

16

14

10

CM

45.72

40.64

35.56

25.4

NOTE 1

Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around).  The duct must be centered
within this opening.

NOTE 2

Distance should be 2 times the diameter of the duct to the nearest
obstruction.

The length of the ductwork from the dryer to the outside exhaust
outlet must not exceed 20 feet (6.09 meters).  The minimum
diameter of this ductwork must be at least 8-inches (20.32
cm) when each pocket/tumbler is vented individually and
10-inches (25.4 cm) when both pockets/tumblers are
combined.  Including tumbler/dryer elbow connections or
elbows used for outside protection from the weather, no more
than 2 90° elbows should be used in the exhaust duct run.  If
more than the equivalent of 2 90° elbows are used, the cross-
sectional area of the ductwork must be increased.

Multiple Dryer (Common) Venting

IMPORTANT:

 For extended ductwork runs, the cross-

sectional area of the ductwork can only be increased to an
extent.  When the ductwork approaches the maximum
limits as noted in this manual, a professional HVAC firm
should be consulted for proper venting information.

If it is not feasible to provide separate exhaust ducts for each
dryer, ducts from individual dryers may be channeled into a
“common main duct.”  The individual ducts should enter the
bottom or side of the main duct at an angle not more than 45º
in the direction of airflow.  The main duct should be tapered,
with the diameter increasing before each individual duct is
added.  The minimum diameter of the individual ductwork
must be at least 8-inches (20.32 cm) for individual pockets/
tumblers or 10-inches (25.4 cm) for individual dryers.

IMPORTANT:

 To maintain proper performance, no more

than 4 dryers should be connected to 1 main common
duct.

A = 20 feet (6.10 meters)
B = 8-inches (20.32 cm)

Single Dryer Venting without Transition Piece

Summary of Contents for MLG-45PDB

Page 1: ...MLG 45PDB Installation Manual Stack Dryer Part No 113489 3 W10185535 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Page 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s ph...

Page 3: ...iminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint sc...

Page 4: ...l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated wit...

Page 5: ...TAINER 8 16 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 1 015 lb 460 40 kg APPROXIMATE SHIPPING WEIGHT 1 080 lb 489 88 kg AIRFLOW PER POCKET 60 Hz 600...

Page 6: ...st be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F...

Page 7: ...from the nearest obstruction 24 inches 60 96 cm is recommended for ease of installation maintenance and service D 1 16 1 5875 mm minimum is required E Flooring should be level or below dryer cabinet f...

Page 8: ...6 in wc 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct...

Page 9: ...uct to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inch...

Page 10: ...ode ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection...

Page 11: ...erials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the...

Page 12: ...nections The dryer is provided with a 3 4 N P T inlet pipe connection on top of the dryer It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servic...

Page 13: ...s desired setting NOTE When a cycle is interrupted by opening the main door cycle time will continue to count downward regardless if the door is open or closed Selection setting changes can be made at...

Page 14: ...r cabinet s avoid using harsh abrasives A product intended for the cleaning of appliances is recommended Adjustments 7 Days After Installation and Every 12 Months Thereafter Inspect bolts nuts screws...

Reviews: