Electrical Information _________________

Electrical Requirements

All electrical connections must be made by a properly licensed
and competent electrician.  This is to ensure that the electrical
installation is adequate and conforms to local, state, and
national regulations or codes of the country of destination.  In
the absence of such codes, all electrical connections,
materials, and workmanship must conform to the applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
For personal safety, the dryer must be electrically grounded
in accordance with local codes and/or the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the
Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or
LATEST EDITION.

IMPORTANT:

 Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this
manual can result in personal injury or component failure.

NOTE: 

Component failure due to improper installation will

void the warranty.

Each pocket should be connected to an independently
protected branch circuit.  The dryer must be connected with
copper wire only.  Do not use aluminum wire.  The copper
conductor wire/cable must be of proper ampacity and
insulation in accordance with electric codes for making all
service connections.

NOTE: 

The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to each
pocket, do not daisy chain.
Component failure due to improper voltage application will
void the warranty.
The manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.

IMPORTANT:

 A separate protected circuit must be

provided to each pocket.
It is necessary to have a power disconnect for each pocket.
These disconnects must be located within 30 feet (9
meters) of the dryer and also be identified as being one of
two power sources supplying a dryer.
The dryer must be connected to the electric supply shown
on the data label.

Electrical Service Specifications

Grounding

A ground (earth) connection must be provided and installed
in accordance with local, state, and national regulations or
codes of the country of destination.  In the absence of these
codes, grounding must conform to applicable requirements
of the National Electrical Code ANSI/NFPA NO. 70-LATEST
EDITION, or in Canada, the installation must conform to
applicable Canada Standards: Canadian Electrical Codes
Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.  The ground
connection may be to a proven earth ground at the location
service panel.

Electrical Connections

If local codes permit, power to the dryer can be made by the
use of a flexible UL listed power cord/pigtail (wire size must
conform to rating of dryer), or the dryer can be hard wired
directly to the service breaker panel.  In both cases, a strain
relief must be installed where the wiring enters the dryer.

ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)

   

NOTES

: A.

 B.
 

When fuses are used they must be dual element, time delay, current limiting, class

RK1 or RK5 ONLY.  Calculate/determine correct fuse value, by applying either local

and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.  For
others, calculate/verify correct breaker size according to appliance amp draw rating
and type of breaker used.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

MINIMUM

WIRE SIZE

*

CIRCUIT

BREAKER

60 Hz

50 Hz

120

2

12

14

15

Single-Phase (1ø)

Wiring Connections/Hookup

The electrical input connections are made into the rear service
box located at the top rear of the dryer.  To gain access, the
service box cover must be removed.

120 Volt Application with Neutral

Remove 3 screws holding down electrical box plate at the
top of the machine.
Remove 2 knockouts provided just in front of electrical box
and insert 3/4” UL listed strain relief into the holes.

* AWG standard type wire ... for individual lengths less than 100 feet (30.48

meters).

1/9/08

Fire Hazard

Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Determine the top pocket electrical connections by
checking wire label, which will be marked “top”.
Connect the top pocket white wire to the white wire
from the top pocket 15-amp service; Connect the
top pocket black wire to the black wire from the top
pocket 15-amp service; Connect the top pocket
green wire to the green wire from the top pocket
ground connection.
The remaining wires will be the bottom pocket
connect as follows:
Connect the bottom pocket white wire to the white
wire from the bottom pocket 15-amp service;
Connect the bottom pocket black wire to the black
wire from the bottom pocket 15-amp service;
Connect the bottom pocket green wire to the green
wire from the bottom pocket ground connection.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical
shock.

 

WARNING

!

Summary of Contents for MLG-45PDB

Page 1: ...MLG 45PDB Installation Manual Stack Dryer Part No 113489 3 W10185535 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Page 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s ph...

Page 3: ...iminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint sc...

Page 4: ...l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated wit...

Page 5: ...TAINER 8 16 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 1 015 lb 460 40 kg APPROXIMATE SHIPPING WEIGHT 1 080 lb 489 88 kg AIRFLOW PER POCKET 60 Hz 600...

Page 6: ...st be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F...

Page 7: ...from the nearest obstruction 24 inches 60 96 cm is recommended for ease of installation maintenance and service D 1 16 1 5875 mm minimum is required E Flooring should be level or below dryer cabinet f...

Page 8: ...6 in wc 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct...

Page 9: ...uct to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inch...

Page 10: ...ode ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection...

Page 11: ...erials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the...

Page 12: ...nections The dryer is provided with a 3 4 N P T inlet pipe connection on top of the dryer It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servic...

Page 13: ...s desired setting NOTE When a cycle is interrupted by opening the main door cycle time will continue to count downward regardless if the door is open or closed Selection setting changes can be made at...

Page 14: ...r cabinet s avoid using harsh abrasives A product intended for the cleaning of appliances is recommended Adjustments 7 Days After Installation and Every 12 Months Thereafter Inspect bolts nuts screws...

Reviews: