Maytag MLG-45PDB Installation Manual Download Page 4

4

Maytag Co.

113489-3  (W10185535)

Important Information ________________

IMPORTANT:

 A means of restraint must be used to prevent

straining of the gas supply when the dryer is moved.
An external means of power removal (disconnect device)
must be provided by the installer.

List of Acronyms _______________________

AWG

American Wire Gauge

HVAC

Heating, Ventilating, and Air-Conditioning

in wc

Inches of Water Column

L.C.D.

Liquid Crystal Display

L.E.D.

Light Emitting Diode

L.P.

Liquid Propane

UL

Underwriters Laboratory

“Caution: Label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper
operation.”
«Attention: Au moment de l’entretien des
commandes, étiquetez tous les fils avant de
les débrancher.  Des erreurs de câblage
peuvent entraîner un fonctionnement
inadéquat et dangereux.»

WARNING

The dryer must never be operated with any
of the back guards or service panels
removed.  Personal injury or fire could result.
The wiring diagram for the dryer is located
behind the front control panel on the right
side.

Table of Contents ________

SPECIFICATIONS ....................................................... 5

INSTALLATION PROCEDURES .................................. 6

Location Requirements ........................................... 6
Dryer Enclosure Requirements ............................... 7
Fresh Air Supply Requirements .............................. 7
Exhaust Requirements ........................................... 7
Electrical Information ............................................ 10
Gas Information ..................................................... 11
Preparation for Operation/Start-Up ........................ 12
Preoperational Test ............................................... 13
Operating Instructions ........................................... 13
Shutdown Instructions .......................................... 13

SERVICE/PARTS INFORMATION ............................. 13

Service .................................................................. 13
Parts ..................................................................... 13

ROUTINE MAINTENANCE ......................................... 13

Cleaning ................................................................ 13
Adjustments ......................................................... 14

DATA LABEL INFORMATION .................................... 14

Summary of Contents for MLG-45PDB

Page 1: ...MLG 45PDB Installation Manual Stack Dryer Part No 113489 3 W10185535 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Page 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s ph...

Page 3: ...iminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint sc...

Page 4: ...l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated wit...

Page 5: ...TAINER 8 16 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 1 015 lb 460 40 kg APPROXIMATE SHIPPING WEIGHT 1 080 lb 489 88 kg AIRFLOW PER POCKET 60 Hz 600...

Page 6: ...st be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F...

Page 7: ...from the nearest obstruction 24 inches 60 96 cm is recommended for ease of installation maintenance and service D 1 16 1 5875 mm minimum is required E Flooring should be level or below dryer cabinet f...

Page 8: ...6 in wc 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct...

Page 9: ...uct to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inch...

Page 10: ...ode ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection...

Page 11: ...erials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the...

Page 12: ...nections The dryer is provided with a 3 4 N P T inlet pipe connection on top of the dryer It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servic...

Page 13: ...s desired setting NOTE When a cycle is interrupted by opening the main door cycle time will continue to count downward regardless if the door is open or closed Selection setting changes can be made at...

Page 14: ...r cabinet s avoid using harsh abrasives A product intended for the cleaning of appliances is recommended Adjustments 7 Days After Installation and Every 12 Months Thereafter Inspect bolts nuts screws...

Reviews: