Maytag MLG-45PDB Installation Manual Download Page 12

12

Maytag Co.

113489-3  (W10185535)

Natural Gas Specifications

**

Nominal

Heating

Value

Supply

Pressure

Gross

Heat Input

Orifice

Size

*

Orifice

(Injector)

Quantity

Burner

Pressure

B tu /ft

3

in wc

Btu/hr

kW

DMS

mm

in wc

1,000

6.0-12.0

224,000

65.64

5

5.2197

2

3.5

The input ratings shown on the data label are for elevations
up to 2,000 feet (610 meters), unless elevation requirements
of over 2,000 feet (610 meters) were specified at the time the
dryer order was placed with the factory.  The adjustment or
conversion of dryers in the field for elevations over 2,000 feet
(610 meters) is made by changing each burner orifice.  If this
conversion is necessary, contact the distributor who sold the
dryer or contact the manufacturer.

IMPORTANT:

 If connection to this dryer is made with a

flexible hose, it must be suitable for the appliance category
in accordance with national installation regulations of the
country of destination, and if in doubt the installer must
contact the supplier.  The manufacturer of this dryer does
not recommend the use of flexible gas supply line/hose.
Pipe joint compounds that resist the action of natural,
propane, and butane gases must be used.

In the U.S.A.: 

An individual manual shutoff valve must be

installed within 6 feet (1.8 meters) of the dryer in accordance
with the National Fuel Gas Code, ANSI Z223.1.

In Canada:

 An individual manual shutoff valve must be

installed in accordance with the B149.1, Natural Gas and
Propane Installation Code.  It is recommended that an
individual manual shutoff valve be installed within 6 feet (1.8
meters) of the dryer.

*

Consult factory for elevations over 2,000 feet (609.6 meters) for correct
burner orifice size(s).

** Btu rating for both tumblers.

Gas Connections

Inlet connection .....3/4” M.N.P.T.
Inlet supply size .... 3/4” Pipe (minimum)

Piping/Connections

The dryer is provided with a 3/4” N.P.T. inlet pipe connection
on top of the dryer.  It is recommended that a gas shutoff valve
be provided to the gas supply line of each dryer for ease in
servicing.
The size of the main gas supply line (header) will vary
depending on the distance this line travels from the gas
meter.  Specific information regarding supply line size should
be determined by the gas supplier.

NOTE: 

Undersized gas supply piping can create a low or

inconsistent pressure, which will result in erratic operation
of the burner ignition system.

TYPICAL NATURAL GAS INSTALLATION

Consistent gas pressure is essential at all gas connections.
It is recommended that a 3/4-inch (19.05 mm) pipe gas loop
be installed in the supply line servicing a bank of dryers.  An
in-line pressure regulator must be installed in the gas supply
line (header) if the (natural) gas pressure exceeds 13.0 in wc
(32.34 mb) pressure.
A plugged tap, accessible for a pressure gauge connection,
must be installed in the main gas supply line immediately
upstream of the dryers.

IMPORTANT:

 Pipe joint compounds that resist the action of

natural, propane, and butane gases must be used.
Test all connections for leaks by brushing on a soapy water
solution (liquid detergent works well).

Preparation for Operation/Start-Up ___

The following items should be checked before attempting to
operate the dryer:
• Read all “WARNING” and “DIRECTION” labels attached

to the dryer.

• Check incoming supply voltage to be sure that it is the

same as indicated on the data label.

• Be sure that all gas shutoff valves are in the open

position.

• Be sure all back panels (guards) and electric box covers

are in place.

• Be sure the service doors are closed and securely in

place.

• Be sure the lint door/drawer is securely in place.
• Rotate the tumbler (drum) by hand to be sure it moves

freely.

• Check bolts, nuts, screws, terminals, and fittings for

tightness and security.

• Check that the vent is connected to the dryer and is

exhausted to the outdoors.

Summary of Contents for MLG-45PDB

Page 1: ...MLG 45PDB Installation Manual Stack Dryer Part No 113489 3 W10185535 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Page 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s ph...

Page 3: ...iminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint sc...

Page 4: ...l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated wit...

Page 5: ...TAINER 8 16 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 1 015 lb 460 40 kg APPROXIMATE SHIPPING WEIGHT 1 080 lb 489 88 kg AIRFLOW PER POCKET 60 Hz 600...

Page 6: ...st be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F...

Page 7: ...from the nearest obstruction 24 inches 60 96 cm is recommended for ease of installation maintenance and service D 1 16 1 5875 mm minimum is required E Flooring should be level or below dryer cabinet f...

Page 8: ...6 in wc 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct...

Page 9: ...uct to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inch...

Page 10: ...ode ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection...

Page 11: ...erials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the...

Page 12: ...nections The dryer is provided with a 3 4 N P T inlet pipe connection on top of the dryer It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servic...

Page 13: ...s desired setting NOTE When a cycle is interrupted by opening the main door cycle time will continue to count downward regardless if the door is open or closed Selection setting changes can be made at...

Page 14: ...r cabinet s avoid using harsh abrasives A product intended for the cleaning of appliances is recommended Adjustments 7 Days After Installation and Every 12 Months Thereafter Inspect bolts nuts screws...

Reviews: