12
See manufacturer for additional configuration options
CONFIGURATION SETTINGS CHART
Configuration Code
Description
Option Code
Description
C1
Interface
0*
Chassis Membrane*
rE
Wireless Remote
L5
Wired Thermostat
C2
Fan Operation
bP
Button present
bA*
7-Button, reverts to Cyclic
A
Always run fan (even in Off)
bC
7-Button, reverts to Continuous
C3
Reverse Cycle Operation
C
Cooler Only
H*
Heat Pump*
0
Service No Operation "Eo"
C4
Room I.D. Digit 1 & 2
00* - 99
00* - 99
C5
Room I.D. Digit 3 & 4
00* - 99
00* - 99
C6
Wired or Wireless Occupancy
0*
Off*
1
On
18
18 Hour Automatic Entry
C8
Temp. Limiting Cool
60* - 72
60* - 72
C9
Temp. Limiting Heat
68 - 90, 80*
68 - 90, 80*
Cd
English / Metric Temp
F*
Fahrenheit Scale*
C
Celsius Scale
d6
Sensorless Un-Occ. Time
1 - 32, 18*
1 - 32, 18*
d7
1st Un-Occ. Set Back Temp.
1 - 16, 2*
1 - 16, 2*
d8
1st Un-Occ. Set Back Time
.1, .5*, 1 - 24
.1 ,.5 ,1 - 24, .5*
d9
2nd Un-Occ. Set Back Temp.
1 - 16, 3*
1 - 16, 3*
dA
2nd Un-Occ. Set Back Time
.1, .5, 1* - 24
(d8) - 24, 1*
db
3rd Un-Occ. Set Back Temp.
1 - 16, 6*
1 - 16, 6*
dC
3rd Un-Occ. Set Back Time
.1, .5, 1 - 24, 3*
(dA) - 24, 3*
dF
Jace Group Code
00* - 99
00* - 99
r4
Room Prefix
00* - 99
00* - 99
r5
Room Suffix
00* - 99
00* - 99