BEFORE BEGINNING INSTALLATION,

PLEASE READ IMPORTANT NOTES BELOW

:

If devices are to be powered, field installed wiring will
need to be run from thermostat location to unit location
and from door sensor location to PTAC location and from
wired magnet to sensor location.

If wireless platform DP01* or DL01E are being utilized,
then room numbers MUST BE CONFIGURED in the control
board prior to binding wireless devices.

All units must have DT01* antenna for wireless devices
to communicate properly.

Sequence of installation:

1) Mount the peripherals

2) Verify operation of the door sensor

3) Program room numbers

4) Bind peripherals

5) Reattach peripherals to their mounted backplates

6) Install optional security screws

Installation and videos are available on our website at
www.amana-ptac.com.

Use only one DD01E Passive Infrared Motion Sensor (PIR)
door switch combination device and/or one DS01G to one
Digi

Smart™

 PTAC unit.

Antenna Installation For DT01* Kit

A DT01* antenna must be installed on the digital PTAC to
allow operation of either the DS01* remote RF thermostat
or a DD01* combination PIR motion sensor and door switch.

Preparation

1. Disconnect power to the unit by unplugging the power

cord at the wall outlet or subbase, or disconnect power
at the fuse box or circuit breaker.

2. If the cabinet front is screwed to the chassis, remove

the 1/4” screw (or screws).  See following figure.

Front Mounting Screw
accessed
through louvers. 

3. Remove cabinet front from chassis by tilting the bottom

of the front forward, lifting slightly up and forward.

4. Mount the antenna as high up on the control panel as

possible and as far to the right as possible in a location
that will not interfere with the reinstallation of the PTAC
polymer room front. Mark holes for screw location.
Remove antenna housing and drill two 1/8” holes where
marked. Some units may have the holes already
predrilled in the correct location.

Wire

DT01* Mounting

5. Remove antenna cable and route cable through opening

in bottom of antenna housing.

6. Mount antenna housing with two screws as shown in

figure.  (

NOTE: 

The Amana

®

 brand logo should be in

the lower right hand corner).

7. Plug wire harness from antenna into connector on the

control board to the right of the master switch, being
careful not to bend and/or break the wires when you
connect the cable to the PTAC.  Gently push the
connector into place by pushing on the edge of the
connector with your thumb nails. 

Avoid pushing directly

on the wires.

8. Restore power to the PTAC unit.

9. Reinstall the polymer room cover.

NOTE: 

The LED must be oriented at the 

top

 of the antenna

housing (the Amana

®

 brand logo will be on the lower right)

for proper unit operation.

Summary of Contents for Amana DD01E

Page 1: ...repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the product safely and to know it well en...

Page 2: ...ower at the fuse box or circuit breaker 2 If the cabinet front is screwed to the chassis remove the 1 4 screw or screws See following figure Front Mounting Screw accessed through louvers 3 Remove cabi...

Page 3: ...bing or other contents behind the wall are unknown 5B Discard flush mount base extension Place the mounting base plate against the wall in the desired location and mark placement of right mounting hol...

Page 4: ...installed in the PTAC unit for the DD01E or DD01F to be operable Skip these steps if not installing 1 Remove motion sensor from mounting plate by pulling apart 2 Mount the back plate on the door trim...

Page 5: ...screw driver push down on the terminal button to open the socket insert wire into socketandreleasetheterminalbutton Insertonewireinto each of the two 2 terminals See following image for wire location...

Page 6: ...obtain 15 16 from back of sensor mounting plate to the center of the magnet If you can easily slide a business card between the magnet and the DD01E or DD01F sensor unit is properly placed vertically...

Page 7: ...Screw location located on each side of sensor SIDE VIEW P O S I T I O N A P O S I T I O N B P O S I T I O N C MAGNET SLOTS MAGNET HOLDER TOP VIEW INSTALL THE MAGNET IN THE CORRECT SLOT 15 16th FROM B...

Page 8: ...hen the door extends into the room beyond the door frame POSITION A Spacers Two 2 1 4 spacers are included in kit CONSTRUCTION STYLE 4 Place magnet in Position A in instances when the door frame exten...

Page 9: ...not accomplished within one minute remove batteries and repeat Steps 1 2 Configuration Settings ThePTACcontrolwillautomaticallyself configuretoworkwiththewallthermostat DS01EKit ifinstalledandbound T...

Page 10: ...ars Then press the up and down arrows to select the room suffix Example For the unit serving the main living area in room 224 press the HEAT key until appears then press the up and down arrow keys to...

Page 11: ...lace 6 Provided optional security screw may be used in the lower center of the thermostat OPTIONAL SECURITY SCREW 7 Snap motion sensor onto motion sensor mounting plate 8 Provided optional security sc...

Page 12: ...00 99 00 99 C5 Room I D Digit 3 4 00 99 00 99 C6 Wired or Wireless Occupancy 0 Off 1 On 18 18 Hour Automatic Entry C8 Temp Limiting Cool 60 72 60 72 C9 Temp Limiting Heat 68 90 80 68 90 80 Cd English...

Page 13: ...back temperature press the HEAT key until feature code comes up To scroll to a previously viewed feature codes press the COOL key Once you have scrolled to the feature press either the up or down arr...

Page 14: ...10 To exit configuration mode Press the OFF key NOTE Configuration feature mode will also automatically exit if no keys are pressed for a period of two 2 minutes The changes made in configuration mode...

Page 15: ...between the equipment and all persons This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations Code of Federal Regulations Chapter 47 part 1...

Page 16: ...to Goodman Company L P Houston TX All rights reserved Goodman Company L P 5151 San Felipe Suite 500 Houston TX 77056 www amana ptac com 2009 2011 2013 2018 Goodman Company L P Due to our policy of co...