background image

 

Please contact Maxwell Technologies directly for any technical specifications critical to application. All products featured on this 
user manual are covered by the following U.S. patents and their respective foreign counterparts: 6643119, 7102877, 7180726 

7203056, 7295423, 7342770, 7352558, 7384433, 7440258, 7492571, 7508651, 7580243, 7791860, 7791861, 7816891, 
7859826, 7883553, 7935155, 7859826, 7883553, 7935155, 8072734, 8098481, 8279580 and patents pending. 

 
MAXWELL TECHNOLOGIES, MAXWELL, MAXWELL CERTIFIED INTEGRATOR, ENABLING ENERGY’S FUTURE, BOOSTCAP, C 

CELL, D CELL, CONDIS, RAD-PAK and their respective designs and/or logos are either trademarks or registered trademarks of 
Maxwell Technologies, Inc. and may not be copied, imitated or used, in whole or in part, without the prior written permission 

Maxwell Technologies, Inc. All contents copyright © 2014 Maxwell Technologies, Inc. All rights reserved. No portion of these 
materials may be reproduced in any form, or by any means, without prior written permission from Maxwell Technologies, Inc.

 

USER MANUAL 
 

Maxwell Technologies

®

 

Ultracapacitor Energy Storage Modules 

 
 
 

Models

16 V Series

48 V Series

 

BMOD0500 P016 B01 

 

BMOD0500 P016 B02 

 

BMOD0250 P016 B01 

 

BMOD0110 P016 B01 

 

BMOD0165 P048 B01 

 

BMOD0110 P048 B01 

 

BMOD0083 P048 B01 

 

BMOD0165 P048 B06 

 

BMOD0165 P048 B09 

 
 
 

Document 1008491  

Downloaded From  

Oneyac.com

Summary of Contents for 16 V Series

Page 1: ...and their respective designs and or logos are either trademarks or registered trademarks of Maxwell Technologies Inc and may not be copied imitated or used in whole or in part without the prior writt...

Page 2: ...ach module contains one temperature monitor output in the form of an NTC thermistor 2 Unpacking and Handling Unpacking 2 1 Inspect the shipping carton for signs of damage prior to unpacking the module...

Page 3: ...ages in excess of 60 V appropriate protection and sealing should be used on both module terminals to avoid shock hazards and corrosion A proper installation should not exert any bending or twisting to...

Page 4: ...dards for the application The anodized coating of the module on the ground connection surface should be removed to ensure an optimal electrical contact Apply a layer of high conductivity anti oxidant...

Page 5: ...modules to prevent undesirable lateral forces on the terminals The energy storage modules have low ESR As a result the resistance of the wires connecting the energy storage module to the application...

Page 6: ...pplied with the module Note The passive version suffix B02 of the BMOD0500 only provides the output of the NTC thermistor for the temperature monitor signal There is no voltage monitoring signal in th...

Page 7: ...istance of the thermistor varies with temperature to provide the actual temperature of the module The thermistor is located inside the module Under normal operating conditions the temperature output s...

Page 8: ...necessary based on the current ratings of attached components Observe polarity indicated on module Do not reverse polarity 5 Safety DANGER HIGH VOLTAGE HAZARD Never touch the power terminals as the m...

Page 9: ...e for example the BK Precision DC Electronic Load Model 8500 or a similar tool 3 If the voltage is under 2V connect the shorting wire provided by Maxwell to the and connectors 4 The module is now safe...

Page 10: ...o avoid false signals or shock hazards In high vibration environments do this every 6 months and in low vibration environments do this annually 7 Storage The discharged module can be stored in the ori...

Page 11: ...ell Technologies Korea Co Ltd Room 1524 D Cube City Office Tower 15F 662 Gyeongin Ro Guro Gu Seoul 152 706 South Korea Phone 82 10 4518 9829 Maxwell Technologies Shanghai Trading Co Ltd Unit A2 C 12th...

Page 12: ...Maxwell Technologies Downloaded From Oneyac com...